[Tue Jul 17 09:49:25 2012] Detection parameters: Position = (126.1, 405.8) = 23 43 36.43 -56 12 54.6 Extent = 10.9" x 10.9", rotation angle = 0 degrees Source counts = 87.2 +/- 12.7 Background counts = 14.5 Rate = 0.0007 +/- 0.0001 [Tue Jul 17 09:49:26 2012] Off-axis axis estimate = 14.72' [Tue Jul 17 09:57:30 2012] Using EEF radius (= 13.79 ")to estimate initial spatial extent for simple fitting [Tue Jul 17 09:57:30 2012] Initial guess for spatial extent in simple fitting = 13.79" [Tue Jul 17 09:57:30 2012] source mask rpix=3.2, npix_max = 53, mask sum = 64, frac = 1.188 [Tue Jul 17 09:57:30 2012] Giving source the simple spatial ID 25 for pass 0, mean size = 13.79" [Tue Jul 17 11:40:25 2012] fullrun_pn_xmm0677770101_pi300-10000_cl_pass0_src25.ximg exists [Tue Jul 17 11:40:25 2012] fullrun_pn_xmm0677770101_pi300-10000_cl_pass0_src25_1.ximg exists [Tue Jul 17 11:40:25 2012] Fit fullrun_pn_xmm0677770101_pi300-10000_cl_pass0_src25 appears to have run properly [Tue Jul 17 11:40:26 2012] fullrun_pn_xmm0677770101_pi300-10000_cl_pass0_tfrozen_src25.ximg exists [Tue Jul 17 11:40:26 2012] fullrun_pn_xmm0677770101_pi300-10000_cl_pass0_tfrozen_src25_1.ximg exists [Tue Jul 17 11:40:26 2012] Fit fullrun_pn_xmm0677770101_pi300-10000_cl_pass0_tfrozen_src25 appears to have run properly [Tue Jul 17 13:34:07 2012] Warning, spatial fit 25 centroid is now closest to src. 40 [Tue Jul 17 13:34:08 2012] Vigneting correction estimate = 1.000000 [Tue Jul 17 13:34:08 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Jul 17 13:34:08 2012] Assessing source extent using major [Tue Jul 17 13:34:08 2012] Source does appear to be extended [Tue Jul 17 13:34:08 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Tue Jul 17 13:34:43 2012] Using EEF radius (= 13.79 ")to estimate initial spatial extent for simple fitting [Tue Jul 17 13:34:43 2012] Initial guess for spatial extent in simple fitting = 13.79" [Tue Jul 17 13:34:43 2012] source mask rpix=3.2, npix_max = 53, mask sum = 64, frac = 1.188 [Tue Jul 17 13:34:43 2012] Giving source the simple spatial ID 25 for pass 1, mean size = 13.79" [Tue Jul 17 14:54:35 2012] fullrun_pn_xmm0677770101_pi300-10000_cl_pass1_src25.ximg exists [Tue Jul 17 14:54:35 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0677770101_pi300-10000_cl_pass1_src25.csv [Tue Jul 17 14:54:35 2012] fullrun_pn_xmm0677770101_pi300-10000_cl_pass1_src25_1.ximg exists [Tue Jul 17 14:54:35 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0677770101_pi300-10000_cl_pass1_src25.csv [Tue Jul 17 14:54:35 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0677770101_pi300-10000_cl_pass1_src25_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0677770101_pi300-10000_cl_pass1_src25.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Tue Jul 17 14:54:36 2012] fullrun_pn_xmm0677770101_pi300-10000_cl_pass1_tfrozen_src25.ximg exists [Tue Jul 17 14:54:36 2012] fullrun_pn_xmm0677770101_pi300-10000_cl_pass1_tfrozen_src25_1.ximg exists [Tue Jul 17 14:54:36 2012] Fit fullrun_pn_xmm0677770101_pi300-10000_cl_pass1_tfrozen_src25 appears to have run properly [Tue Jul 17 16:24:04 2012] Source 41 is offset by 4.622160 and -7.530823 pixels which is larger than 2 X fitted extent = 2.644372 x 2.644372, not incorporating fit results [Tue Jul 17 16:24:04 2012] Warning: source 25 in spatial fitting list does not appear to have a counterpart in memory, closest src. was src. 41 at 14.052631 pixels away [Tue Jul 17 16:24:04 2012] Vigneting correction estimate = 1.000000 [Tue Jul 17 16:24:04 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Jul 17 16:24:04 2012] Assessing source extent using major [Tue Jul 17 16:24:04 2012] Source does appear to be extended [Tue Jul 17 16:24:04 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Tue Jul 17 16:24:47 2012] XMMSAS src. selection expression = ellipse(10922.352531, 35259.210632, 652.500000, 652.500000, 0.000000, X, Y) [Tue Jul 17 16:24:47 2012] Writing source region out to fullrun_pn_xmm0677770101_pi300-10000_pass1_cl_src41_src.reg [Tue Jul 17 16:24:47 2012] Extracting stamp from image fullrun_pn_xmm0677770101_pi300-10000_cl_sm2.00.img.gz, (89, 368) - (164, 443) [Tue Jul 17 16:24:47 2012] XMMSAS bgd. selection expression = annulus(10922.352531, 35259.210632, 1087.500000, 2175.000000, X, Y) && !ellipse(13015.745560, 33686.581024, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(10524.546000, 35904.712000, 429.269612, 429.269612, 0.000000, X, Y) [Tue Jul 17 16:24:47 2012] Writing fullrun_pn_xmm0677770101_pi300-10000_pass1_cl_src41.gif [Tue Jul 17 17:44:38 2012] Mean detx,y = (-6323.79, 1754.38) [Tue Jul 17 17:44:54 2012] Setting backscal keywords in source and bgd. spectrum [Tue Jul 17 17:45:19 2012] Binned source spectrum to 10 counts/bin [Tue Jul 17 17:45:19 2012] Setting source spectrum file to fullrun_pn_xmm0677770101_pi300-10000_pass1_cl_src41_src_b10.pi.gz [Tue Jul 17 17:45:19 2012] Setting bgd. spectrum file to fullrun_pn_xmm0677770101_pi300-10000_pass1_cl_src41_bgd.pi.gz [Tue Jul 17 19:24:30 2012] Not generating rmf since there are only 87 counts [Tue Jul 17 19:24:30 2012] rmf not generated due to insufficient counts [Tue Jul 17 20:40:20 2012] Updating aperture counts using extracted products [Tue Jul 17 20:40:20 2012] Error reading totcts from fullrun_pn_xmm0677770101_pi300-10000_pass1_cl_src41_src_b10.pi.gz [Tue Jul 17 20:40:21 2012] Calculating source flux in energy range 0.30-8.00 [Tue Jul 17 20:40:21 2012] Using photon index=1.80, rate=0.000671, arf fullrun_pn_xmm0677770101_pi300-10000_pass1_cl_src41.arf [Tue Jul 17 20:40:21 2012] Assuming count rate is from the 0.30-10.00 bandpass [Tue Jul 17 20:40:21 2012] Getting flux using calc_pl_flux failed [Tue Jul 17 20:41:09 2012] Simple spatial fitting not done (or not done successfully), skipping spectral fitting