Source List

Observation details report
Detailed source parameters (including errors) in a comma-separated values file

Click on source number for detailed analysis, including spectral fits if applicable

data idnum idradec telescope instrument x y cnts cntserr rate rateerr SNR poisprob sigmaj sigmin incang offax cnts_soft cnts_hard hr hr_err ext var N_H flux vign flags
Report srcpi bgdpi arf rmf 1 X042002.00-502250.4 xmm pn 280.164 313.55 113.799 18.9932 0.0208779 0.00348454 7.24171 1 4.81766 4.81766 0 1.72473 F F 4.38586 3.3843e-14 1 dbsxf
Report srcpi bgdpi arf 1 X042001.98-502249.6 xmm mos1 280.215 313.751 31.8112 8.73445 0.00569091 0.00156256 4.96495 0.999996 6.30427 6.30427 0 1.70644 F F 4.38642 6.20511e-14 1 dsx
Report srcpi bgdpi arf 2 X042044.47-501829.6 xmm mos1 186.609 373.352 13.1528 7.12578 0.00235299 0.00127478 2.05283 0.978435 3.5585 1.14495 105.731 9.74711 F T 4.28812 8.39112e-14 1 dsx
Report srcpi bgdpi arf 1 X042001.75-502247.8 xmm mos2 280.713 314.151 22.8836 7.95232 0.00409385 0.00142266 3.60223 0.999642 3.49782 3.49782 0 1.70777 F F 4.38681 5.82368e-14 1 dbsx

counts and rate are bgd.-subtracted, based on simple spatial fitting (if done) or extracted counts from aperture otherwise (N.B., in either case aperture counts are given csv file).
cntserr, rateerr = Error on (source) counts and count rate, based on error in total counts
SNR = signal-to-noise ratio, computed using Nsrc/sqrt(Nbgd)
poisprob = Poisson probability of observing total counts given bgd. counts
sigmaj, sigmin = source extent (from detection output or spatial fitting) in units of arcsecs.
incang = position angle of source (inclination from x-axis)
cnts_soft = bgd.-subtracted counts in soft band (0.50 - 2.00 KeV, always taken directly from source aperture rather than model fitting)
cnts_hard = bgd.-subtracted counts in hard band (2.00 - 10.00 KeV, always taken directly from source aperture rather than model fitting)
hr, hr_err = hardness ratio ([cnts_hard-cnts_soft]/[cnts_hard+cnts_soft]) and error
ext = source extension flag: F = false (not extended), A = true (extended), A = asymetric (ratio of sigmaj/sigmin > 1 + x, where x = 0.5 by default)
var = variability flag: U = unknown, F = false (is not variable), T = true
N_H = Galactic column density as determined from LHEASOFT nh program
flux = flux determined from count rate using pimms (in the 0.30-8.00 keV bandpass for a power-law model with ph. index = 1.8)
vign = vignetting correction
Flags: d = detection parameters, s = simple spatial fitting parameters, b = simple spatial fitting failed, p = poor simple spatial fit, x = extracted events parameters, t = temporal anaylsis parameters, i = psf spatial fitting parameters, f = spectral fitting parameters, c = source is confused, u = user-defined source, v = detected source coincident with user-defined source, r = source is in region-of-interest