skip = machinename x3.localdomain process id = 7000: smart_fit pl logroot=fullrun_mos2_xmm0553910801_pi300-10000_pass1_cl_src1_pl flux_elow=0.300000 flux_ehi=8.000000 2 parameters in pl dchi = 4.605 F(2.0-10.0 keV) = 2.67e-13 Count rates: 0.01816 Entry point parameter values: Nh = 1.11e-08 () Gamma = 1.7 () Starting error search... Getting error on parameter #2 = Nh smart_error exited normally Hard limit reached before req. deltachisq for lower bound Nh = 1.11e-08 (0 - 0.0621) Getting error on parameter #3 = Gamma smart_error exited normally Gamma = 1.7 (1.47 - 2.04) Saving fit as fullrun_mos2_xmm0553910801_pi300-10000_pass1_cl_src1_pl_new.xcm in order to save the revised "delta" values (to improve future error search efficiency) Final chisq(dof) = 19.583(21) F(0.5-2.0 keV) = 1.471e-13 F(2.0-10.0 keV) = 2.67e-13 F(0.3-8.0) = 4.099e-13 Count rates: 0.01816