[Thu Mar 29 13:06:41 2012] Detection parameters: Position = (401.8, 338.1) = 0 42 13.01 41 18 38.3 Extent = 10.9" x 10.9", rotation angle = 0 degrees Source counts = 294.0 +/- 36.3 Background counts = 5.6 Rate = 0.09 +/- 0.01 [Thu Mar 29 13:06:48 2012] Off-axis axis estimate = 8.02' [Thu Mar 29 20:42:39 2012] Using EEF radius (= 10.44 ")to estimate initial spatial extent for simple fitting [Thu Mar 29 20:42:39 2012] Setting initial spatial extent for simple fitting to maximum allowed for this pass [Thu Mar 29 20:42:39 2012] Initial guess for spatial extent in simple fitting = 10.44" [Thu Mar 29 20:42:39 2012] source mask rpix=2.4, npix_max = 33, mask sum = 14, frac = 0.416 [Thu Mar 29 20:42:39 2012] Skipping simple spatial due to low active detector fraction [Fri Mar 30 03:54:15 2012] Source 6 is offset by -4.226104 and -7.881928 pixels which is larger than 2 X fitted extent = 1.251549 x 1.251549, not incorporating fit results [Fri Mar 30 03:54:16 2012] Vigneting correction estimate = 1.000000 [Fri Mar 30 03:54:16 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Fri Mar 30 03:54:16 2012] Assessing source extent using major [Fri Mar 30 03:54:16 2012] Source does appear to be extended [Fri Mar 30 03:54:16 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Fri Mar 30 09:10:36 2012] Using EEF radius (= 10.44 ")to estimate initial spatial extent for simple fitting [Fri Mar 30 09:10:36 2012] Initial guess for spatial extent in simple fitting = 10.44" [Fri Mar 30 09:10:36 2012] source mask rpix=2.4, npix_max = 33, mask sum = 14, frac = 0.416 [Fri Mar 30 09:10:36 2012] Skipping simple spatial due to low active detector fraction [Fri Mar 30 16:39:43 2012] Vigneting correction estimate = 1.000000 [Fri Mar 30 16:39:43 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Fri Mar 30 16:39:43 2012] Assessing source extent using major [Fri Mar 30 16:39:43 2012] Source does appear to be extended [Fri Mar 30 16:39:43 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Sat Mar 31 04:14:50 2012] XMMSAS src. selection expression = ellipse(34904.750946, 29368.850250, 652.500000, 652.500000, 0.000000, X, Y) [Sat Mar 31 04:14:50 2012] Writing source region out to fullrun_mos1_xmm0551690601_pi300-10000_pass1_cl_src6_src.reg [Sat Mar 31 04:14:50 2012] Extracting stamp from image fullrun_mos1_xmm0551690601_pi300-10000_cl_sm2.00.img.gz, (364, 301) - (439, 376) [Sat Mar 31 04:14:50 2012] XMMSAS bgd. selection expression = annulus(34904.750946, 29368.850250, 1087.500000, 2175.000000, X, Y) && !ellipse(36128.982300, 29117.976532, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(35123.257202, 28657.278503, 870.000000, 870.000000, 0.000000, X, Y) [Sat Mar 31 04:14:50 2012] Writing fullrun_mos1_xmm0551690601_pi300-10000_pass1_cl_src6.gif [Sat Mar 31 04:18:24 2012] Mean detx,y = (6893.97, 3549.05) [Sat Mar 31 04:18:27 2012] Setting backscal keywords in source and bgd. spectrum [Sat Mar 31 04:19:10 2012] Binned source spectrum to 10 counts/bin [Sat Mar 31 04:19:11 2012] Setting source spectrum file to fullrun_mos1_xmm0551690601_pi300-10000_pass1_cl_src6_src_b10.pi.gz [Sat Mar 31 04:19:11 2012] Setting bgd. spectrum file to fullrun_mos1_xmm0551690601_pi300-10000_pass1_cl_src6_bgd.pi.gz [Sat Mar 31 05:30:56 2012] Not generating rmf since RequireSpatial is true but spatial fitting not done [Sat Mar 31 05:30:56 2012] rmf not generated due to insufficient counts [Sat Mar 31 09:26:16 2012] Updating aperture counts using extracted products [Sat Mar 31 09:26:16 2012] Error reading totcts from fullrun_mos1_xmm0551690601_pi300-10000_pass1_cl_src6_src_b10.pi.gz [Sat Mar 31 09:26:20 2012] Calculating source flux in energy range 0.30-8.00 [Sat Mar 31 09:26:20 2012] Using photon index=1.80, rate=0.0878, arf fullrun_mos1_xmm0551690601_pi300-10000_pass1_cl_src6.arf [Sat Mar 31 09:26:20 2012] Assuming count rate is from the 0.30-10.00 bandpass [Sat Mar 31 09:26:20 2012] Updating source flux to 2.2e-12 [Sat Mar 31 09:26:35 2012] Simple spatial fitting not done (or not done successfully), skipping spectral fitting