[Tue Dec 27 03:24:48 2011] Detection parameters: Position = (152.1, 433.1) = 7 18 8.05 -62 12 29.9 Extent = 10.9" x 10.9", rotation angle = 0 degrees Source counts = 195.5 +/- 26.1 Background counts = 166.8 Rate = 0.005 +/- 0.0007 [Tue Dec 27 03:24:50 2011] Off-axis axis estimate = 14.42' [Tue Dec 27 03:34:49 2011] Using EEF radius (= 13.64 ")to estimate initial spatial extent for simple fitting [Tue Dec 27 03:34:49 2011] Setting initial spatial extent for simple fitting to maximum allowed for this pass [Tue Dec 27 03:34:49 2011] Initial guess for spatial extent in simple fitting = 13.64" [Tue Dec 27 03:34:49 2011] source mask rpix=3.1, npix_max = 52, mask sum = 64, frac = 1.211 [Tue Dec 27 03:34:49 2011] Giving source the simple spatial ID 1 for pass 0, mean size = 13.64" [Tue Dec 27 04:31:51 2011] fullrun_pn_xmm0550460101_pi300-10000_cl_pass0_src1.ximg exists [Tue Dec 27 04:31:51 2011] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0550460101_pi300-10000_cl_pass0_src1.csv [Tue Dec 27 04:31:51 2011] fullrun_pn_xmm0550460101_pi300-10000_cl_pass0_src1_1.ximg exists [Tue Dec 27 04:31:51 2011] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0550460101_pi300-10000_cl_pass0_src1.csv [Tue Dec 27 04:31:51 2011] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0550460101_pi300-10000_cl_pass0_src1_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0550460101_pi300-10000_cl_pass0_src1.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Tue Dec 27 04:31:51 2011] fullrun_pn_xmm0550460101_pi300-10000_cl_pass0_tfrozen_src1.ximg exists [Tue Dec 27 04:31:51 2011] fullrun_pn_xmm0550460101_pi300-10000_cl_pass0_tfrozen_src1_1.ximg exists [Tue Dec 27 04:31:51 2011] Fit fullrun_pn_xmm0550460101_pi300-10000_cl_pass0_tfrozen_src1 appears to have run properly [Tue Dec 27 05:54:38 2011] Spatial fit model total counts = 624.998000, observed total counts = 625.000000 [Tue Dec 27 05:54:38 2011] Offset between fit and detection position for source 1 = 0.186805 pixels [Tue Dec 27 05:54:38 2011] 625.558000 total counts/ 560.701000 bgd. counts: snr = 2.738995 Spatial fit parameters: Offset between fit and detection position for source 1 = 0.186805 pixels Position = (152.2, 433.3) = 7 18 7.99 -62 12 31.0 Extent = 5.1 (3.8-7.5)", rotation angle = 0 Source counts = 64.9 +/- 25.0 Background counts = 560.7 Rate = 0.003 +/- 0.001 [Tue Dec 27 05:54:38 2011] Vigneting correction estimate = 1.000000 [Tue Dec 27 05:54:38 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Dec 27 05:54:38 2011] Assessing source extent using major axis lower bound [Tue Dec 27 05:54:38 2011] Source does appear to be extended [Tue Dec 27 05:54:38 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Tue Dec 27 05:55:04 2011] Using previous fit value to estimate initial spatial extent for simple fitting [Tue Dec 27 05:55:04 2011] Initial guess for spatial extent in simple fitting = 5.13" [Tue Dec 27 05:55:04 2011] source mask rpix=1.2, npix_max = 11, mask sum = 12, frac = 1.064 [Tue Dec 27 05:55:04 2011] Giving source the simple spatial ID 1 for pass 1, mean size = 5.13" [Tue Dec 27 06:50:26 2011] fullrun_pn_xmm0550460101_pi300-10000_cl_pass1_src1.ximg exists [Tue Dec 27 06:50:26 2011] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0550460101_pi300-10000_cl_pass1_src1.csv [Tue Dec 27 06:50:26 2011] fullrun_pn_xmm0550460101_pi300-10000_cl_pass1_src1_1.ximg exists [Tue Dec 27 06:50:26 2011] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0550460101_pi300-10000_cl_pass1_src1.csv [Tue Dec 27 06:50:26 2011] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0550460101_pi300-10000_cl_pass1_src1_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0550460101_pi300-10000_cl_pass1_src1.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Tue Dec 27 06:50:26 2011] fullrun_pn_xmm0550460101_pi300-10000_cl_pass1_tfrozen_src1.ximg exists [Tue Dec 27 06:50:26 2011] fullrun_pn_xmm0550460101_pi300-10000_cl_pass1_tfrozen_src1_1.ximg exists [Tue Dec 27 06:50:26 2011] Fit fullrun_pn_xmm0550460101_pi300-10000_cl_pass1_tfrozen_src1 appears to have run properly [Tue Dec 27 08:05:12 2011] Spatial fit model total counts = 320.000000, observed total counts = 320.000000 [Tue Dec 27 08:05:12 2011] Offset between fit and detection position for source 1 = 0.062481 pixels [Tue Dec 27 08:05:12 2011] 321.674900 total counts/ 264.473000 bgd. counts: snr = 3.517384 Spatial fit parameters: Offset between fit and detection position for source 1 = 0.062481 pixels Position = (152.1, 433.2) = 7 18 8.00 -62 12 31.2 Extent = 4.5 (3.4-6.7)", rotation angle = 0 Source counts = 57.2 +/- 17.9 Background counts = 264.5 Rate = 0.003 +/- 0.0009 [Tue Dec 27 08:05:12 2011] Vigneting correction estimate = 1.000000 [Tue Dec 27 08:05:12 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Dec 27 08:05:12 2011] Assessing source extent using major axis lower bound [Tue Dec 27 08:05:12 2011] Source does appear to be extended [Tue Dec 27 08:05:12 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Tue Dec 27 08:05:36 2011] XMMSAS src. selection expression = ellipse(13188.507520, 37641.857800, 269.800808, 269.800808, 0.000000, X, Y) [Tue Dec 27 08:05:36 2011] Writing source region out to fullrun_pn_xmm0550460101_pi300-10000_pass1_cl_src1_src.reg [Tue Dec 27 08:05:36 2011] Extracting stamp from image fullrun_pn_xmm0550460101_pi300-10000_cl_sm2.00.img.gz, (137, 418) - (168, 449) [Tue Dec 27 08:05:36 2011] XMMSAS bgd. selection expression = annulus(13188.507520, 37641.857800, 449.668013, 899.336026, X, Y) [Tue Dec 27 08:05:36 2011] Writing fullrun_pn_xmm0550460101_pi300-10000_pass1_cl_src1.gif [Tue Dec 27 08:06:02 2011] Mean detx,y = (-4524.23, -15483.50) [Tue Dec 27 08:06:10 2011] Setting backscal keywords in source and bgd. spectrum [Tue Dec 27 08:06:43 2011] Binned source spectrum to 10 counts/bin [Tue Dec 27 08:06:44 2011] Setting source spectrum file to fullrun_pn_xmm0550460101_pi300-10000_pass1_cl_src1_src_b10.pi.gz [Tue Dec 27 08:06:44 2011] Setting bgd. spectrum file to fullrun_pn_xmm0550460101_pi300-10000_pass1_cl_src1_bgd.pi.gz [Tue Dec 27 08:29:11 2011] Not generating rmf since there are only 57 counts [Tue Dec 27 08:29:11 2011] rmf not generated due to insufficient counts [Tue Dec 27 10:21:24 2011] Updating aperture counts using extracted products [Tue Dec 27 10:21:24 2011] Error reading totcts from fullrun_pn_xmm0550460101_pi300-10000_pass1_cl_src1_src_b10.pi.gz [Tue Dec 27 10:21:25 2011] Calculating source flux in energy range 0.30-8.00 [Tue Dec 27 10:21:25 2011] Using photon index=1.80, rate=0.00278, arf fullrun_pn_xmm0550460101_pi300-10000_pass1_cl_src1.arf [Tue Dec 27 10:21:25 2011] Assuming count rate is from the 0.30-10.00 bandpass [Tue Dec 27 10:21:25 2011] Updating source flux to 3.3e-14 [Tue Dec 27 10:23:09 2011] Source 1 has fewer than 100.000000 counts, skipping spectral fitting [Tue Dec 27 10:23:47 2011] xmm0550460101/analysis//spectral/fullrun_pn_xmm0550460101_pi300-10000_pass1_cl_src1_pl.csv not found, spectral fit skipped or did not complete