[Mon Feb 27 09:19:40 2012] Detection parameters: Position = (429.6, 309.0) = 0 38 58.13 40 58 34.7 Extent = 10.9" x 10.9", rotation angle = 0 degrees Source counts = 63.9 +/- 11.1 Background counts = 14.6 Rate = 0.003 +/- 0.0005 [Mon Feb 27 09:19:40 2012] Off-axis axis estimate = 9.54' [Mon Feb 27 11:36:05 2012] Using EEF radius (= 11.20 ")to estimate initial spatial extent for simple fitting [Mon Feb 27 11:36:05 2012] Initial guess for spatial extent in simple fitting = 11.20" [Mon Feb 27 11:36:05 2012] source mask rpix=2.6, npix_max = 37, mask sum = 36, frac = 0.952 [Mon Feb 27 11:36:05 2012] Giving source the simple spatial ID 9 for pass 0, mean size = 11.20" [Mon Feb 27 12:36:59 2012] fullrun_mos1_xmm0511380301_pi300-10000_cl_pass0_src9.ximg exists [Mon Feb 27 12:36:59 2012] fullrun_mos1_xmm0511380301_pi300-10000_cl_pass0_src9_1.ximg exists [Mon Feb 27 12:36:59 2012] Fit fullrun_mos1_xmm0511380301_pi300-10000_cl_pass0_src9 appears to have run properly [Mon Feb 27 12:36:59 2012] fullrun_mos1_xmm0511380301_pi300-10000_cl_pass0_tfrozen_src9.ximg exists [Mon Feb 27 12:36:59 2012] fullrun_mos1_xmm0511380301_pi300-10000_cl_pass0_tfrozen_src9_1.ximg exists [Mon Feb 27 12:36:59 2012] Fit fullrun_mos1_xmm0511380301_pi300-10000_cl_pass0_tfrozen_src9 appears to have run properly [Mon Feb 27 13:45:06 2012] Warning: source 9 in spatial fitting list does not appear to have a counterpart in memory, closest src. was src. 16 at 12.340355 pixels away [Mon Feb 27 13:45:06 2012] Vigneting correction estimate = 1.000000 [Mon Feb 27 13:45:06 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Mon Feb 27 13:45:06 2012] Assessing source extent using major [Mon Feb 27 13:45:06 2012] Source does appear to be extended [Mon Feb 27 13:45:06 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Mon Feb 27 13:45:06 2012] Source is confused with source 18 [Mon Feb 27 16:37:21 2012] Using EEF radius (= 11.20 ")to estimate initial spatial extent for simple fitting [Mon Feb 27 16:37:21 2012] Setting initial spatial extent for simple fitting to maximum allowed for this pass [Mon Feb 27 16:37:21 2012] Initial guess for spatial extent in simple fitting = 11.20" [Mon Feb 27 16:37:21 2012] source mask rpix=2.6, npix_max = 37, mask sum = 36, frac = 0.952 [Mon Feb 27 16:37:21 2012] Giving source the simple spatial ID 9 for pass 1, mean size = 11.20" [Mon Feb 27 17:35:57 2012] fullrun_mos1_xmm0511380301_pi300-10000_cl_pass1_src9.ximg exists [Mon Feb 27 17:35:57 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_mos1_xmm0511380301_pi300-10000_cl_pass1_src9.csv [Mon Feb 27 17:35:57 2012] fullrun_mos1_xmm0511380301_pi300-10000_cl_pass1_src9_1.ximg exists [Mon Feb 27 17:35:57 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_mos1_xmm0511380301_pi300-10000_cl_pass1_src9.csv [Mon Feb 27 17:35:57 2012] It looks like the fit did not converge You should probably delete fullrun_mos1_xmm0511380301_pi300-10000_cl_pass1_src9_1.ximg Either tweak this fit manually starting from fullrun_mos1_xmm0511380301_pi300-10000_cl_pass1_src9.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Mon Feb 27 17:35:57 2012] fullrun_mos1_xmm0511380301_pi300-10000_cl_pass1_tfrozen_src9.ximg exists [Mon Feb 27 17:35:57 2012] fullrun_mos1_xmm0511380301_pi300-10000_cl_pass1_tfrozen_src9_1.ximg exists [Mon Feb 27 17:35:57 2012] Fit fullrun_mos1_xmm0511380301_pi300-10000_cl_pass1_tfrozen_src9 appears to have run properly [Mon Feb 27 18:38:26 2012] Warning: source 9 in spatial fitting list does not appear to have a counterpart in memory, closest src. was src. 16 at 14.854203 pixels away [Mon Feb 27 18:38:26 2012] Vigneting correction estimate = 1.000000 [Mon Feb 27 18:38:26 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Mon Feb 27 18:38:26 2012] Assessing source extent using major [Mon Feb 27 18:38:26 2012] Source does appear to be extended [Mon Feb 27 18:38:26 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Mon Feb 27 20:54:41 2012] XMMSAS src. selection expression = ellipse(37326.275726, 26838.840973, 652.500000, 652.500000, 0.000000, X, Y) [Mon Feb 27 20:54:41 2012] Writing source region out to fullrun_mos1_xmm0511380301_pi300-10000_pass1_cl_src16_src.reg [Mon Feb 27 20:54:41 2012] Extracting stamp from image fullrun_mos1_xmm0511380301_pi300-10000_cl_sm2.00.img.gz, (392, 272) - (467, 347) [Mon Feb 27 20:54:41 2012] XMMSAS bgd. selection expression = annulus(37326.275726, 26838.840973, 1087.500000, 2175.000000, X, Y) && !ellipse(38484.348000, 26150.046000, 1836.480053, 1836.480053, 0.000000, X, Y) [Mon Feb 27 20:54:41 2012] Writing fullrun_mos1_xmm0511380301_pi300-10000_pass1_cl_src16.gif [Mon Feb 27 20:58:15 2012] Mean detx,y = (3638.19, 8981.50) [Mon Feb 27 20:58:17 2012] Setting backscal keywords in source and bgd. spectrum [Mon Feb 27 20:58:36 2012] Binned source spectrum to 10 counts/bin [Mon Feb 27 20:58:36 2012] Setting source spectrum file to fullrun_mos1_xmm0511380301_pi300-10000_pass1_cl_src16_src_b10.pi.gz [Mon Feb 27 20:58:36 2012] Setting bgd. spectrum file to fullrun_mos1_xmm0511380301_pi300-10000_pass1_cl_src16_bgd.pi.gz [Mon Feb 27 21:18:36 2012] Not generating rmf since there are only 63 counts [Mon Feb 27 21:18:36 2012] rmf not generated due to insufficient counts [Mon Feb 27 22:06:36 2012] Updating aperture counts using extracted products [Mon Feb 27 22:06:36 2012] Error reading totcts from fullrun_mos1_xmm0511380301_pi300-10000_pass1_cl_src16_src_b10.pi.gz [Mon Feb 27 22:06:37 2012] Calculating source flux in energy range 0.30-8.00 [Mon Feb 27 22:06:37 2012] Using photon index=1.80, rate=0.00273, arf fullrun_mos1_xmm0511380301_pi300-10000_pass1_cl_src16.arf [Mon Feb 27 22:06:37 2012] Assuming count rate is from the 0.30-10.00 bandpass [Mon Feb 27 22:06:37 2012] Updating source flux to 4.1e-14 [Mon Feb 27 22:06:43 2012] Simple spatial fitting not done (or not done successfully), skipping spectral fitting