[Fri Dec 23 02:21:36 2011] Detection parameters: Position = (454.4, 401.3) = 17 48 15.03 -27 16 22.9 Extent = 10.9" x 10.9", rotation angle = 0 degrees Source counts = 56.7 +/- 14.0 Background counts = 42.7 Rate = 0.008 +/- 0.002 [Fri Dec 23 02:21:38 2011] Off-axis axis estimate = 13.55' [Fri Dec 23 02:26:12 2011] Using EEF radius (= 13.20 ")to estimate initial spatial extent for simple fitting [Fri Dec 23 02:26:12 2011] Setting initial spatial extent for simple fitting to maximum allowed for this pass [Fri Dec 23 02:26:12 2011] Initial guess for spatial extent in simple fitting = 13.20" [Fri Dec 23 02:26:12 2011] source mask rpix=3.0, npix_max = 49, mask sum = 49, frac = 0.980 [Fri Dec 23 02:26:12 2011] Giving source the simple spatial ID 3 for pass 0, mean size = 13.20" [Fri Dec 23 03:44:54 2011] fullrun_pn_xmm0511010301_pi300-10000_cl_pass0_src3.ximg exists [Fri Dec 23 03:44:54 2011] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0511010301_pi300-10000_cl_pass0_src3.csv [Fri Dec 23 03:44:54 2011] fullrun_pn_xmm0511010301_pi300-10000_cl_pass0_src3_1.ximg exists [Fri Dec 23 03:44:54 2011] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0511010301_pi300-10000_cl_pass0_src3.csv [Fri Dec 23 03:44:54 2011] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0511010301_pi300-10000_cl_pass0_src3_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0511010301_pi300-10000_cl_pass0_src3.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Fri Dec 23 03:44:54 2011] fullrun_pn_xmm0511010301_pi300-10000_cl_pass0_tfrozen_src3.ximg exists [Fri Dec 23 03:44:54 2011] fullrun_pn_xmm0511010301_pi300-10000_cl_pass0_tfrozen_src3_1.ximg exists [Fri Dec 23 03:44:54 2011] Fit fullrun_pn_xmm0511010301_pi300-10000_cl_pass0_tfrozen_src3 appears to have run properly [Fri Dec 23 06:40:18 2011] Spatial fit model total counts = 733.604000, observed total counts = 736.000000 [Fri Dec 23 06:40:18 2011] Offset between fit and detection position for source 3 = 4.926445 pixels [Fri Dec 23 06:40:18 2011] 705.739000 total counts/ 501.789000 bgd. counts: snr = 9.104648 Spatial fit parameters: Offset between fit and detection position for source 3 = 4.926445 pixels Position = (457.5, 405.1) = 17 48 14.02 -27 16 5.6 Extent = 20.6 (16.9-26.4)", rotation angle = 0 Source counts = 203.9 +/- 26.6 Background counts = 501.8 Rate = 0.04 +/- 0.005 [Fri Dec 23 06:40:18 2011] Vigneting correction estimate = 1.000000 [Fri Dec 23 06:40:18 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Fri Dec 23 06:40:18 2011] Assessing source extent using major axis lower bound [Fri Dec 23 06:40:18 2011] Source does appear to be extended [Fri Dec 23 06:40:18 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Fri Dec 23 06:40:43 2011] Using previous fit value to estimate initial spatial extent for simple fitting [Fri Dec 23 06:40:43 2011] Initial guess for spatial extent in simple fitting = 20.56" [Fri Dec 23 06:40:43 2011] source mask rpix=4.7, npix_max = 109, mask sum = 110, frac = 1.006 [Fri Dec 23 06:40:43 2011] Giving source the simple spatial ID 3 for pass 1, mean size = 20.56" [Fri Dec 23 07:48:08 2011] fullrun_pn_xmm0511010301_pi300-10000_cl_pass1_src3.ximg exists [Fri Dec 23 07:48:08 2011] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0511010301_pi300-10000_cl_pass1_src3.csv [Fri Dec 23 07:48:08 2011] fullrun_pn_xmm0511010301_pi300-10000_cl_pass1_src3_1.ximg exists [Fri Dec 23 07:48:08 2011] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0511010301_pi300-10000_cl_pass1_src3.csv [Fri Dec 23 07:48:08 2011] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0511010301_pi300-10000_cl_pass1_src3_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0511010301_pi300-10000_cl_pass1_src3.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Fri Dec 23 07:48:08 2011] fullrun_pn_xmm0511010301_pi300-10000_cl_pass1_tfrozen_src3.ximg exists [Fri Dec 23 07:48:08 2011] fullrun_pn_xmm0511010301_pi300-10000_cl_pass1_tfrozen_src3_1.ximg exists [Fri Dec 23 07:48:08 2011] Fit fullrun_pn_xmm0511010301_pi300-10000_cl_pass1_tfrozen_src3 appears to have run properly [Fri Dec 23 10:56:44 2011] Warning, spatial fit 3 centroid is now closest to src. 6 [Fri Dec 23 10:56:44 2011] Vigneting correction estimate = 1.000000 [Fri Dec 23 10:56:44 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Fri Dec 23 10:56:44 2011] Assessing source extent using major axis lower bound [Fri Dec 23 10:56:44 2011] Source does appear to be extended [Fri Dec 23 10:56:44 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Fri Dec 23 10:56:44 2011] Source is confused with source 6 [Fri Dec 23 10:57:09 2011] XMMSAS src. selection expression = ellipse(39757.250000, 35197.118000, 1233.822036, 1233.822036, 0.000000, X, Y) [Fri Dec 23 10:57:09 2011] Writing source region out to fullrun_pn_xmm0511010301_pi300-10000_pass1_cl_src3_src.reg [Fri Dec 23 10:57:09 2011] Extracting stamp from image fullrun_pn_xmm0511010301_pi300-10000_cl_sm2.00.img.gz, (387, 334) - (528, 476) [Fri Dec 23 10:57:09 2011] XMMSAS bgd. selection expression = annulus(39757.250000, 35197.118000, 2056.370059, 4112.740118, X, Y) && !ellipse(41584.250000, 34414.118000, 1645.096047, 1645.096047, 0.000000, X, Y) && !ellipse(40471.252000, 34098.966000, 3290.192095, 3290.192095, 0.000000, X, Y) && !ellipse(37335.167419, 32307.489777, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(34021.494000, 31228.316000, 1732.048050, 1732.048050, 0.000000, X, Y) [Fri Dec 23 10:57:09 2011] Writing fullrun_pn_xmm0511010301_pi300-10000_pass1_cl_src3.gif [Fri Dec 23 11:02:23 2011] Mean detx,y = (-14770.40, 10493.55) [Fri Dec 23 11:02:30 2011] Setting backscal keywords in source and bgd. spectrum [Fri Dec 23 11:04:08 2011] Binned source spectrum to 10 counts/bin [Fri Dec 23 11:04:08 2011] Setting source spectrum file to fullrun_pn_xmm0511010301_pi300-10000_pass1_cl_src3_src_b10.pi.gz [Fri Dec 23 11:04:08 2011] Setting bgd. spectrum file to fullrun_pn_xmm0511010301_pi300-10000_pass1_cl_src3_bgd.pi.gz [Fri Dec 23 13:35:43 2011] Updating aperture counts using extracted products [Fri Dec 23 13:35:43 2011] Error reading totcts from fullrun_pn_xmm0511010301_pi300-10000_pass1_cl_src3_src_b10.pi.gz [Fri Dec 23 13:35:44 2011] Calculating source flux in energy range 0.30-8.00 [Fri Dec 23 13:35:44 2011] Using photon index=1.80, rate=0.0395, arf fullrun_pn_xmm0511010301_pi300-10000_pass1_cl_src3.arf [Fri Dec 23 13:35:44 2011] Assuming count rate is from the 0.30-10.00 bandpass [Fri Dec 23 13:35:44 2011] Updating source flux to 3.5e-13 [Fri Dec 23 13:38:26 2011] Flag c found in src. 3 procflags, skipping spectral fitting