skip = machinename x3.localdomain process id = 15914: smart_fit pl logroot=fullrun_mos1_xmm0505720401_pi300-10000_pass1_cl_src29_pl flux_elow=0.300000 flux_ehi=8.000000 2 parameters in pl dchi = 4.605 F(2.0-10.0 keV) = 2.133e-13 Count rates: 0.01466 Entry point parameter values: Nh = 0.0656 () Gamma = 1.43 () Starting error search... Getting error on parameter #2 = Nh smart_error exited normally Hard limit reached before req. deltachisq for lower bound Nh = 0.0656 (0 - 0.224) Getting error on parameter #3 = Gamma smart_error exited normally Gamma = 1.43 (1.1 - 1.86) Saving fit as fullrun_mos1_xmm0505720401_pi300-10000_pass1_cl_src29_pl_new.xcm in order to save the revised "delta" values (to improve future error search efficiency) Final chisq(dof) = 33.350(31) F(0.5-2.0 keV) = 6.639e-14 F(2.0-10.0 keV) = 2.133e-13 F(0.3-8.0) = 2.436e-13 Count rates: 0.01466