skip = machinename x3.localdomain process id = 31337: smart_fit pl logroot=fullrun_mos1_xmm0504101001_pi300-10000_pass1_cl_src4_pl flux_elow=0.300000 flux_ehi=8.000000 2 parameters in pl dchi = 4.605 F(2.0-10.0 keV) = 1.193e-13 Count rates: 0.01297 Entry point parameter values: Nh = 0.0464 () Gamma = 1.82 () Starting error search... Getting error on parameter #2 = Nh smart_error exited normally Hard limit reached before req. deltachisq for lower bound Nh = 0.0464 (0 - 0.148) Getting error on parameter #3 = Gamma smart_error exited normally Gamma = 1.82 (1.45 - 2.33) Saving fit as fullrun_mos1_xmm0504101001_pi300-10000_pass1_cl_src4_pl_new.xcm in order to save the revised "delta" values (to improve future error search efficiency) Final chisq(dof) = 17.945(24) F(0.5-2.0 keV) = 6.839e-14 F(2.0-10.0 keV) = 1.193e-13 F(0.3-8.0) = 1.809e-13 Count rates: 0.01297