skip = machinename x3.localdomain process id = 26313: smart_fit pl logroot=fullrun_pn_xmm0502220301_pi300-10000_pass1_cl_src16_pl flux_elow=0.300000 flux_ehi=8.000000 2 parameters in pl dchi = 4.605 F(2.0-10.0 keV) = 4.317e-15 Count rates: 0.004275 Entry point parameter values: Nh = 0.0938 () Gamma = 2.75 () Starting error search... Getting error on parameter #2 = Nh smart_error exited normally Hard limit reached before req. deltachisq for lower bound Nh = 0.0938 (0 - 0.302) Getting error on parameter #3 = Gamma smart_error exited normally Gamma = 2.75 (1.94 - 4.31) Saving fit as fullrun_pn_xmm0502220301_pi300-10000_pass1_cl_src16_pl_new.xcm in order to save the revised "delta" values (to improve future error search efficiency) Final chisq(dof) = 31.446(36) F(0.5-2.0 keV) = 8.119e-15 F(2.0-10.0 keV) = 4.317e-15 F(0.3-8.0) = 1.41e-14 Count rates: 0.004275