skip = machinename x3.localdomain process id = 28137: smart_fit pl logroot=fullrun_pn_xmm0502140101_pi300-10000_pass1_cl_src9_pl flux_elow=0.300000 flux_ehi=8.000000 2 parameters in pl dchi = 4.605 F(2.0-10.0 keV) = 1.848e-12 Count rates: -0.02446 Entry point parameter values: Nh = 6.1 () Gamma = 2.39 () Starting error search... Getting error on parameter #2 = Nh smart_error exited normally Nh = 6.1 (4.13 - 8.71) Getting error on parameter #3 = Gamma smart_error exited normally Gamma = 2.39 (1.63 - 3.37) Saving fit as fullrun_pn_xmm0502140101_pi300-10000_pass1_cl_src9_pl_new.xcm in order to save the revised "delta" values (to improve future error search efficiency) Final chisq(dof) = 872.834(572) F(0.5-2.0 keV) = 2.534e-14 F(2.0-10.0 keV) = 1.848e-12 F(0.3-8.0) = 1.574e-12 Count rates: -0.02446