skip = machinename x3.localdomain process id = 20284: smart_fit pl logroot=fullrun_mos1_xmm0502140101_pi300-10000_pass1_cl_src36_pl flux_elow=0.300000 flux_ehi=8.000000 2 parameters in pl dchi = 4.605 F(2.0-10.0 keV) = 2.188e-14 Count rates: 0.001682 Entry point parameter values: Nh = 0.635 () Gamma = 2.58 () Starting error search... Getting error on parameter #2 = Nh smart_error exited normally Nh = 0.635 (0.287 - 1.2) Getting error on parameter #3 = Gamma smart_error exited normally Gamma = 2.58 (1.67 - 4.04) Saving fit as fullrun_mos1_xmm0502140101_pi300-10000_pass1_cl_src36_pl_new.xcm in order to save the revised "delta" values (to improve future error search efficiency) Final chisq(dof) = 11.269(18) F(0.5-2.0 keV) = 1.136e-14 F(2.0-10.0 keV) = 2.188e-14 F(0.3-8.0) = 3.122e-14 Count rates: 0.001682