[Wed Jul 18 18:48:40 2012] Detection parameters: Position = (295.3, 340.5) = 18 56 39.79 -37 52 57.2 Extent = 10.9" x 10.9", rotation angle = 0 degrees Source counts = 86.0 +/- 16.4 Background counts = 45.8 Rate = 0.0009 +/- 0.0002 [Wed Jul 18 18:48:40 2012] Off-axis axis estimate = 3.05' [Wed Jul 18 19:02:07 2012] Using EEF radius (= 7.96 ")to estimate initial spatial extent for simple fitting [Wed Jul 18 19:02:07 2012] Initial guess for spatial extent in simple fitting = 7.96" [Wed Jul 18 19:02:07 2012] source mask rpix=1.8, npix_max = 21, mask sum = 20, frac = 0.922 [Wed Jul 18 19:02:07 2012] Giving source the simple spatial ID 31 for pass 0, mean size = 7.96" [Wed Jul 18 22:35:40 2012] fullrun_mos1_xmm0412601501_pi300-10000_cl_pass0_src31.ximg exists [Wed Jul 18 22:35:40 2012] fullrun_mos1_xmm0412601501_pi300-10000_cl_pass0_src31_1.ximg exists [Wed Jul 18 22:35:40 2012] Fit fullrun_mos1_xmm0412601501_pi300-10000_cl_pass0_src31 appears to have run properly [Wed Jul 18 22:35:41 2012] fullrun_mos1_xmm0412601501_pi300-10000_cl_pass0_tfrozen_src31.ximg exists [Wed Jul 18 22:35:41 2012] fullrun_mos1_xmm0412601501_pi300-10000_cl_pass0_tfrozen_src31_1.ximg exists [Wed Jul 18 22:35:41 2012] Fit fullrun_mos1_xmm0412601501_pi300-10000_cl_pass0_tfrozen_src31 appears to have run properly [Thu Jul 19 00:33:33 2012] Source 44 is offset by -0.021279 and 1.192799 pixels which is larger than 2 X fitted extent = 0.978952 x 0.978952, not incorporating fit results [Thu Jul 19 00:33:33 2012] Spatial fit model total counts = -85.347200, observed total counts = 373.000000 [Thu Jul 19 00:33:33 2012] Poor agreement between spatial fit and data for source 44 It may help to tweak spatial fit manually Not incorporating fit results [Thu Jul 19 00:33:33 2012] Vigneting correction estimate = 1.000000 [Thu Jul 19 00:33:33 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Thu Jul 19 00:33:33 2012] Assessing source extent using major [Thu Jul 19 00:33:33 2012] Source does appear to be extended [Thu Jul 19 00:33:33 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Thu Jul 19 00:33:33 2012] Source is confused with source 38 [Thu Jul 19 00:52:30 2012] Using EEF radius (= 7.96 ")to estimate initial spatial extent for simple fitting [Thu Jul 19 00:52:30 2012] Initial guess for spatial extent in simple fitting = 7.96" [Thu Jul 19 00:52:30 2012] source mask rpix=1.8, npix_max = 21, mask sum = 20, frac = 0.922 [Thu Jul 19 00:52:30 2012] Giving source the simple spatial ID 29 for pass 1, mean size = 7.96" [Thu Jul 19 03:06:00 2012] fullrun_mos1_xmm0412601501_pi300-10000_cl_pass1_src29.ximg exists [Thu Jul 19 03:06:00 2012] fullrun_mos1_xmm0412601501_pi300-10000_cl_pass1_src29_1.ximg exists [Thu Jul 19 03:06:00 2012] Fit fullrun_mos1_xmm0412601501_pi300-10000_cl_pass1_src29 appears to have run properly [Thu Jul 19 03:06:01 2012] fullrun_mos1_xmm0412601501_pi300-10000_cl_pass1_tfrozen_src29.ximg exists [Thu Jul 19 03:06:01 2012] fullrun_mos1_xmm0412601501_pi300-10000_cl_pass1_tfrozen_src29_1.ximg exists [Thu Jul 19 03:06:01 2012] Fit fullrun_mos1_xmm0412601501_pi300-10000_cl_pass1_tfrozen_src29 appears to have run properly [Thu Jul 19 04:00:16 2012] Source 44 is offset by -1.033398 and 6.767606 pixels which is larger than 2 X fitted extent = 1.233264 x 1.233264, not incorporating fit results [Thu Jul 19 04:00:16 2012] Vigneting correction estimate = 1.000000 [Thu Jul 19 04:00:16 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Thu Jul 19 04:00:16 2012] Assessing source extent using major [Thu Jul 19 04:00:16 2012] Source does appear to be extended [Thu Jul 19 04:00:16 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Thu Jul 19 04:37:00 2012] XMMSAS src. selection expression = ellipse(25640.562531, 29570.807709, 652.500000, 652.500000, 0.000000, X, Y) [Thu Jul 19 04:37:00 2012] Writing source region out to fullrun_mos1_xmm0412601501_pi300-10000_pass1_cl_src44_src.reg [Thu Jul 19 04:37:00 2012] Extracting stamp from image fullrun_mos1_xmm0412601501_pi300-10000_cl_sm2.00.img.gz, (258, 303) - (333, 378) [Thu Jul 19 04:37:00 2012] XMMSAS bgd. selection expression = annulus(25640.562531, 29570.807709, 1087.500000, 2175.000000, X, Y) && !ellipse(26561.628800, 27415.895000, 1283.018437, 1283.018437, 0.000000, X, Y) && !ellipse(28065.047668, 28049.908691, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(28046.215546, 29218.087067, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(29151.548000, 30038.606000, 1362.312039, 1362.312039, 0.000000, X, Y) && !ellipse(26482.727203, 30325.359070, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(27162.058929, 30187.767487, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(22698.885651, 27820.625671, 870.000000, 870.000000, 0.000000, X, Y) [Thu Jul 19 04:37:00 2012] Writing fullrun_mos1_xmm0412601501_pi300-10000_pass1_cl_src44.gif [Thu Jul 19 04:49:06 2012] Mean detx,y = (2099.12, -1476.28) [Thu Jul 19 04:49:07 2012] Setting backscal keywords in source and bgd. spectrum [Thu Jul 19 04:49:15 2012] Binned source spectrum to 10 counts/bin [Thu Jul 19 04:49:15 2012] Setting source spectrum file to fullrun_mos1_xmm0412601501_pi300-10000_pass1_cl_src44_src_b10.pi.gz [Thu Jul 19 04:49:15 2012] Setting bgd. spectrum file to fullrun_mos1_xmm0412601501_pi300-10000_pass1_cl_src44_bgd.pi.gz [Thu Jul 19 05:19:10 2012] Not generating rmf since there are only 85 counts [Thu Jul 19 05:19:10 2012] rmf not generated due to insufficient counts [Thu Jul 19 06:50:45 2012] Updating aperture counts using extracted products [Thu Jul 19 06:50:45 2012] Error reading totcts from fullrun_mos1_xmm0412601501_pi300-10000_pass1_cl_src44_src_b10.pi.gz [Thu Jul 19 06:50:46 2012] Calculating source flux in energy range 0.30-8.00 [Thu Jul 19 06:50:46 2012] Using photon index=1.80, rate=0.000947, arf fullrun_mos1_xmm0412601501_pi300-10000_pass1_cl_src44.arf [Thu Jul 19 06:50:46 2012] Assuming count rate is from the 0.30-10.00 bandpass [Thu Jul 19 06:50:46 2012] Updating source flux to 1e-14 [Thu Jul 19 06:50:48 2012] Simple spatial fitting not done (or not done successfully), skipping spectral fitting