[Mon Mar 19 21:17:28 2012] Detection parameters: Position = (285.9, 346.4) = 10 0 28.65 2 17 44.9 Extent = 10.9" x 10.9", rotation angle = 0 degrees Source counts = 156.6 +/- 16.6 Background counts = 27.4 Rate = 0.008 +/- 0.0008 [Mon Mar 19 21:17:30 2012] Off-axis axis estimate = 3.60' [Mon Mar 19 21:21:35 2012] Using EEF radius (= 8.23 ")to estimate initial spatial extent for simple fitting [Mon Mar 19 21:21:35 2012] Initial guess for spatial extent in simple fitting = 8.23" [Mon Mar 19 21:21:35 2012] source mask rpix=1.9, npix_max = 22, mask sum = 25, frac = 1.093 [Mon Mar 19 21:21:35 2012] Giving source the simple spatial ID 14 for pass 0, mean size = 8.23" [Mon Mar 19 23:31:41 2012] fullrun_pn_xmm0203361301_pi300-10000_cl_pass0_src14.ximg exists [Mon Mar 19 23:31:41 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0203361301_pi300-10000_cl_pass0_src14.csv [Mon Mar 19 23:31:41 2012] fullrun_pn_xmm0203361301_pi300-10000_cl_pass0_src14_1.ximg exists [Mon Mar 19 23:31:41 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0203361301_pi300-10000_cl_pass0_src14.csv [Mon Mar 19 23:31:41 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0203361301_pi300-10000_cl_pass0_src14_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0203361301_pi300-10000_cl_pass0_src14.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Mon Mar 19 23:31:41 2012] fullrun_pn_xmm0203361301_pi300-10000_cl_pass0_tfrozen_src14.ximg exists [Mon Mar 19 23:31:41 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0203361301_pi300-10000_cl_pass0_tfrozen_src14.csv [Mon Mar 19 23:31:41 2012] fullrun_pn_xmm0203361301_pi300-10000_cl_pass0_tfrozen_src14_1.ximg exists [Mon Mar 19 23:31:41 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0203361301_pi300-10000_cl_pass0_tfrozen_src14.csv [Mon Mar 19 23:31:41 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0203361301_pi300-10000_cl_pass0_tfrozen_src14_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0203361301_pi300-10000_cl_pass0_tfrozen_src14.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Tue Mar 20 00:52:12 2012] Warning: source 14 in spatial fitting list does not appear to have a counterpart in memory, closest src. was src. 14 at 11.205922 pixels away [Tue Mar 20 00:52:12 2012] Vigneting correction estimate = 1.000000 [Tue Mar 20 00:52:12 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Mar 20 00:52:12 2012] Assessing source extent using major [Tue Mar 20 00:52:12 2012] Source does appear to be extended [Tue Mar 20 00:52:12 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Tue Mar 20 00:52:38 2012] Using EEF radius (= 8.23 ")to estimate initial spatial extent for simple fitting [Tue Mar 20 00:52:38 2012] Initial guess for spatial extent in simple fitting = 8.23" [Tue Mar 20 00:52:38 2012] source mask rpix=1.9, npix_max = 22, mask sum = 25, frac = 1.093 [Tue Mar 20 00:52:38 2012] Giving source the simple spatial ID 13 for pass 1, mean size = 8.23" [Tue Mar 20 02:29:16 2012] fullrun_pn_xmm0203361301_pi300-10000_cl_pass1_src13.ximg exists [Tue Mar 20 02:29:16 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0203361301_pi300-10000_cl_pass1_src13.csv [Tue Mar 20 02:29:16 2012] fullrun_pn_xmm0203361301_pi300-10000_cl_pass1_src13_1.ximg exists [Tue Mar 20 02:29:16 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0203361301_pi300-10000_cl_pass1_src13.csv [Tue Mar 20 02:29:16 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0203361301_pi300-10000_cl_pass1_src13_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0203361301_pi300-10000_cl_pass1_src13.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Tue Mar 20 02:29:17 2012] fullrun_pn_xmm0203361301_pi300-10000_cl_pass1_tfrozen_src13.ximg exists [Tue Mar 20 02:29:17 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0203361301_pi300-10000_cl_pass1_tfrozen_src13.csv [Tue Mar 20 02:29:17 2012] fullrun_pn_xmm0203361301_pi300-10000_cl_pass1_tfrozen_src13_1.ximg exists [Tue Mar 20 02:29:17 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0203361301_pi300-10000_cl_pass1_tfrozen_src13.csv [Tue Mar 20 02:29:17 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0203361301_pi300-10000_cl_pass1_tfrozen_src13_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0203361301_pi300-10000_cl_pass1_tfrozen_src13.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Tue Mar 20 03:52:20 2012] Spatial fit model total counts = 367.502000, observed total counts = 328.000000 [Tue Mar 20 03:52:20 2012] Poor agreement between spatial fit and data for source 14 It may help to tweak spatial fit manually Not incorporating fit results [Tue Mar 20 03:52:20 2012] Vigneting correction estimate = 1.000000 [Tue Mar 20 03:52:20 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Mar 20 03:52:20 2012] Assessing source extent using major [Tue Mar 20 03:52:20 2012] Source does appear to be extended [Tue Mar 20 03:52:20 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Tue Mar 20 03:52:50 2012] XMMSAS src. selection expression = ellipse(24822.465698, 30089.600433, 652.500000, 652.500000, 0.000000, X, Y) [Tue Mar 20 03:52:50 2012] Writing source region out to fullrun_pn_xmm0203361301_pi300-10000_pass1_cl_src14_src.reg [Tue Mar 20 03:52:50 2012] Extracting stamp from image fullrun_pn_xmm0203361301_pi300-10000_cl_sm2.00.img.gz, (248, 309) - (323, 384) [Tue Mar 20 03:52:50 2012] XMMSAS bgd. selection expression = annulus(24822.465698, 30089.600433, 1087.500000, 2175.000000, X, Y) && !ellipse(23807.336960, 30636.730600, 498.952014, 498.952014, 0.000000, X, Y) [Tue Mar 20 03:52:50 2012] Writing fullrun_pn_xmm0203361301_pi300-10000_pass1_cl_src14.gif [Tue Mar 20 04:04:08 2012] Mean detx,y = (-1543.10, 5763.73) [Tue Mar 20 04:04:15 2012] Setting backscal keywords in source and bgd. spectrum [Tue Mar 20 04:04:40 2012] Binned source spectrum to 10 counts/bin [Tue Mar 20 04:04:41 2012] Setting source spectrum file to fullrun_pn_xmm0203361301_pi300-10000_pass1_cl_src14_src_b10.pi.gz [Tue Mar 20 04:04:41 2012] Setting bgd. spectrum file to fullrun_pn_xmm0203361301_pi300-10000_pass1_cl_src14_bgd.pi.gz [Tue Mar 20 04:56:00 2012] Not generating rmf since RequireSpatial is true but spatial fitting not done [Tue Mar 20 04:56:00 2012] rmf not generated due to insufficient counts [Tue Mar 20 05:40:55 2012] Updating aperture counts using extracted products [Tue Mar 20 05:40:55 2012] Error reading totcts from fullrun_pn_xmm0203361301_pi300-10000_pass1_cl_src14_src_b10.pi.gz [Tue Mar 20 05:40:58 2012] Calculating source flux in energy range 0.30-8.00 [Tue Mar 20 05:40:58 2012] Using photon index=1.80, rate=0.00751, arf fullrun_pn_xmm0203361301_pi300-10000_pass1_cl_src14.arf [Tue Mar 20 05:40:58 2012] Assuming count rate is from the 0.30-10.00 bandpass [Tue Mar 20 05:40:58 2012] Updating source flux to 2.5e-14 [Tue Mar 20 05:41:10 2012] Simple spatial fitting not done (or not done successfully), skipping spectral fitting