[Tue Aug 21 23:39:45 2012] Detection parameters: Position = (312.3, 457.9) = 11 31 50.24 -34 23 4.8 Extent = 10.9" x 10.9", rotation angle = 0 degrees Source counts = 30.9 +/- 7.4 Background counts = 6.1 Rate = 0.001 +/- 0.0002 [Tue Aug 21 23:39:46 2012] Off-axis axis estimate = 11.60' [Wed Aug 22 02:22:57 2012] Using EEF radius (= 12.23 ")to estimate initial spatial extent for simple fitting [Wed Aug 22 02:22:57 2012] Initial guess for spatial extent in simple fitting = 12.23" [Wed Aug 22 02:22:57 2012] source mask rpix=2.8, npix_max = 43, mask sum = 42, frac = 0.957 [Wed Aug 22 02:22:57 2012] Giving source the simple spatial ID 33 for pass 0, mean size = 12.23" [Wed Aug 22 03:14:51 2012] fullrun_mos2_xmm0112880101_pi300-10000_cl_pass0_src33.ximg exists [Wed Aug 22 03:14:51 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_mos2_xmm0112880101_pi300-10000_cl_pass0_src33.csv [Wed Aug 22 03:14:51 2012] fullrun_mos2_xmm0112880101_pi300-10000_cl_pass0_src33_1.ximg exists [Wed Aug 22 03:14:51 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_mos2_xmm0112880101_pi300-10000_cl_pass0_src33.csv [Wed Aug 22 03:14:51 2012] It looks like the fit did not converge You should probably delete fullrun_mos2_xmm0112880101_pi300-10000_cl_pass0_src33_1.ximg Either tweak this fit manually starting from fullrun_mos2_xmm0112880101_pi300-10000_cl_pass0_src33.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Wed Aug 22 03:14:52 2012] fullrun_mos2_xmm0112880101_pi300-10000_cl_pass0_tfrozen_src33.ximg exists [Wed Aug 22 03:14:52 2012] fullrun_mos2_xmm0112880101_pi300-10000_cl_pass0_tfrozen_src33_1.ximg exists [Wed Aug 22 03:14:52 2012] Fit fullrun_mos2_xmm0112880101_pi300-10000_cl_pass0_tfrozen_src33 appears to have run properly [Wed Aug 22 03:15:12 2012] Source 16 is offset by -4.178303 and 1.353856 pixels which is larger than 2 X fitted extent = 1.466635 x 1.466635, not incorporating fit results [Wed Aug 22 03:15:12 2012] Warning: source 33 in spatial fitting list does not appear to have a counterpart in memory, closest src. was src. 16 at 15.798100 pixels away [Wed Aug 22 03:15:12 2012] Vigneting correction estimate = 1.000000 [Wed Aug 22 03:15:12 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Wed Aug 22 03:15:12 2012] Assessing source extent using major [Wed Aug 22 03:15:12 2012] Source does appear to be extended [Wed Aug 22 03:15:12 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Wed Aug 22 06:13:14 2012] Using EEF radius (= 12.23 ")to estimate initial spatial extent for simple fitting [Wed Aug 22 06:13:14 2012] Initial guess for spatial extent in simple fitting = 12.23" [Wed Aug 22 06:13:14 2012] source mask rpix=2.8, npix_max = 43, mask sum = 42, frac = 0.957 [Wed Aug 22 06:13:14 2012] Giving source the simple spatial ID 26 for pass 1, mean size = 12.23" [Wed Aug 22 06:49:08 2012] fullrun_mos2_xmm0112880101_pi300-10000_cl_pass1_src26.ximg exists [Wed Aug 22 06:49:08 2012] fullrun_mos2_xmm0112880101_pi300-10000_cl_pass1_src26_1.ximg exists [Wed Aug 22 06:49:08 2012] Fit fullrun_mos2_xmm0112880101_pi300-10000_cl_pass1_src26 appears to have run properly [Wed Aug 22 06:49:08 2012] fullrun_mos2_xmm0112880101_pi300-10000_cl_pass1_tfrozen_src26.ximg exists [Wed Aug 22 06:49:08 2012] fullrun_mos2_xmm0112880101_pi300-10000_cl_pass1_tfrozen_src26_1.ximg exists [Wed Aug 22 06:49:08 2012] Fit fullrun_mos2_xmm0112880101_pi300-10000_cl_pass1_tfrozen_src26 appears to have run properly [Wed Aug 22 06:49:27 2012] Warning: source 26 in spatial fitting list does not appear to have a counterpart in memory, closest src. was src. 16 at 16.914908 pixels away [Wed Aug 22 06:49:27 2012] Vigneting correction estimate = 1.000000 [Wed Aug 22 06:49:27 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Wed Aug 22 06:49:27 2012] Assessing source extent using major [Wed Aug 22 06:49:27 2012] Source does appear to be extended [Wed Aug 22 06:49:27 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Wed Aug 22 09:23:23 2012] XMMSAS src. selection expression = ellipse(27122.655640, 39787.437439, 652.500000, 652.500000, 0.000000, X, Y) [Wed Aug 22 09:23:23 2012] Writing source region out to fullrun_mos2_xmm0112880101_pi300-10000_pass1_cl_src16_src.reg [Wed Aug 22 09:23:23 2012] Extracting stamp from image fullrun_mos2_xmm0112880101_pi300-10000_cl_sm2.00.img.gz, (275, 420) - (350, 495) [Wed Aug 22 09:23:23 2012] XMMSAS bgd. selection expression = annulus(27122.655640, 39787.437439, 1087.500000, 2175.000000, X, Y) && !ellipse(26532.347800, 40537.940800, 1054.968030, 244.608007, 37.622000, X, Y) [Wed Aug 22 09:23:23 2012] Writing fullrun_mos2_xmm0112880101_pi300-10000_pass1_cl_src16.gif [Wed Aug 22 09:29:25 2012] Mean detx,y = (9816.50, -12540.98) [Wed Aug 22 09:29:26 2012] Setting backscal keywords in source and bgd. spectrum [Wed Aug 22 09:29:44 2012] Binned source spectrum to 10 counts/bin [Wed Aug 22 09:29:44 2012] Setting source spectrum file to fullrun_mos2_xmm0112880101_pi300-10000_pass1_cl_src16_src_b10.pi.gz [Wed Aug 22 09:29:44 2012] Setting bgd. spectrum file to fullrun_mos2_xmm0112880101_pi300-10000_pass1_cl_src16_bgd.pi.gz [Wed Aug 22 09:46:33 2012] Not generating rmf since there are only 30 counts [Wed Aug 22 09:46:33 2012] rmf not generated due to insufficient counts [Wed Aug 22 09:47:11 2012] Updating aperture counts using extracted products [Wed Aug 22 09:47:11 2012] Error reading totcts from fullrun_mos2_xmm0112880101_pi300-10000_pass1_cl_src16_src_b10.pi.gz [Wed Aug 22 09:47:11 2012] Calculating source flux in energy range 0.30-8.00 [Wed Aug 22 09:47:11 2012] Using photon index=1.80, rate=0.00105, arf fullrun_mos2_xmm0112880101_pi300-10000_pass1_cl_src16.arf [Wed Aug 22 09:47:11 2012] Assuming count rate is from the 0.30-10.00 bandpass [Wed Aug 22 09:47:11 2012] Updating source flux to 3e-14 [Wed Aug 22 09:47:21 2012] Simple spatial fitting not done (or not done successfully), skipping spectral fitting