[Wed Oct 5 01:50:28 2011] Detection parameters: Position = (249.5, 445.6) = 12 9 50.18 43 53 29.1 Extent = 10.9" x 10.9", rotation angle = 0 degrees Source counts = 53.2 +/- 9.2 Background counts = 9.2 Rate = 0.005 +/- 0.0009 [Wed Oct 5 01:50:28 2011] Off-axis axis estimate = 11.24' [Wed Oct 5 01:51:34 2011] Using EEF radius (= 12.05 ")to estimate initial spatial extent for simple fitting [Wed Oct 5 01:51:34 2011] Initial guess for spatial extent in simple fitting = 12.05" [Wed Oct 5 01:51:34 2011] source mask rpix=2.8, npix_max = 42, mask sum = 43, frac = 1.005 [Wed Oct 5 01:51:34 2011] Giving source the simple spatial ID 8 for pass 0, mean size = 12.05" [Wed Oct 5 02:26:06 2011] fullrun_pn_xmm0112551201_pi300-10000_cl_pass0_src8.ximg exists [Wed Oct 5 02:26:06 2011] fullrun_pn_xmm0112551201_pi300-10000_cl_pass0_src8_1.ximg exists [Wed Oct 5 02:26:06 2011] Fit fullrun_pn_xmm0112551201_pi300-10000_cl_pass0_src8 appears to have run properly [Wed Oct 5 02:26:07 2011] fullrun_pn_xmm0112551201_pi300-10000_cl_pass0_tfrozen_src8.ximg exists [Wed Oct 5 02:26:07 2011] fullrun_pn_xmm0112551201_pi300-10000_cl_pass0_tfrozen_src8_1.ximg exists [Wed Oct 5 02:26:07 2011] Fit fullrun_pn_xmm0112551201_pi300-10000_cl_pass0_tfrozen_src8 appears to have run properly [Wed Oct 5 03:07:28 2011] Spatial fit model total counts = 98.126600, observed total counts = 106.000000 [Wed Oct 5 03:07:28 2011] Offset between fit and detection position for source 8 = 0.017285 pixels [Wed Oct 5 03:07:28 2011] 93.841700 total counts/ 53.460900 bgd. counts: snr = 5.522768 Spatial fit parameters: Offset between fit and detection position for source 8 = 0.017285 pixels Position = (249.5, 445.6) = 12 9 50.19 43 53 27.0 Extent = 5.0 (3.9-6.2)", rotation angle = 0 Source counts = 40.4 +/- 9.7 Background counts = 53.5 Rate = 0.004 +/- 0.001 [Wed Oct 5 03:07:28 2011] Vigneting correction estimate = 1.000000 [Wed Oct 5 03:07:28 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Wed Oct 5 03:07:28 2011] Assessing source extent using major axis lower bound [Wed Oct 5 03:07:28 2011] Source does appear to be extended [Wed Oct 5 03:07:28 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Wed Oct 5 03:07:41 2011] Using previous fit value to estimate initial spatial extent for simple fitting [Wed Oct 5 03:07:41 2011] Initial guess for spatial extent in simple fitting = 4.97" [Wed Oct 5 03:07:41 2011] source mask rpix=1.1, npix_max = 10, mask sum = 9, frac = 0.835 [Wed Oct 5 03:07:41 2011] Giving source the simple spatial ID 8 for pass 1, mean size = 4.97" [Wed Oct 5 03:38:52 2011] fullrun_pn_xmm0112551201_pi300-10000_cl_pass1_src8.ximg exists [Wed Oct 5 03:38:52 2011] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0112551201_pi300-10000_cl_pass1_src8.csv [Wed Oct 5 03:38:52 2011] fullrun_pn_xmm0112551201_pi300-10000_cl_pass1_src8_1.ximg exists [Wed Oct 5 03:38:52 2011] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0112551201_pi300-10000_cl_pass1_src8.csv [Wed Oct 5 03:38:52 2011] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0112551201_pi300-10000_cl_pass1_src8_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0112551201_pi300-10000_cl_pass1_src8.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Wed Oct 5 03:38:52 2011] fullrun_pn_xmm0112551201_pi300-10000_cl_pass1_tfrozen_src8.ximg exists [Wed Oct 5 03:38:52 2011] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0112551201_pi300-10000_cl_pass1_tfrozen_src8.csv [Wed Oct 5 03:38:52 2011] fullrun_pn_xmm0112551201_pi300-10000_cl_pass1_tfrozen_src8_1.ximg exists [Wed Oct 5 03:38:52 2011] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0112551201_pi300-10000_cl_pass1_tfrozen_src8.csv [Wed Oct 5 03:38:52 2011] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0112551201_pi300-10000_cl_pass1_tfrozen_src8_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0112551201_pi300-10000_cl_pass1_tfrozen_src8.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Wed Oct 5 04:14:26 2011] Warning, spatial fit 8 centroid is now closest to src. 6 [Wed Oct 5 04:14:26 2011] Vigneting correction estimate = 1.000000 [Wed Oct 5 04:14:26 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Wed Oct 5 04:14:26 2011] Assessing source extent using major axis lower bound [Wed Oct 5 04:14:26 2011] Source does appear to be extended [Wed Oct 5 04:14:26 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Wed Oct 5 04:14:37 2011] XMMSAS src. selection expression = ellipse(21659.348600, 38716.837200, 297.996551, 297.996551, 0.000000, X, Y) [Wed Oct 5 04:14:37 2011] Writing source region out to fullrun_pn_xmm0112551201_pi300-10000_pass1_cl_src8_src.reg [Wed Oct 5 04:14:37 2011] Extracting stamp from image fullrun_pn_xmm0112551201_pi300-10000_cl_sm2.00.img.gz, (232, 428) - (267, 463) [Wed Oct 5 04:14:37 2011] XMMSAS bgd. selection expression = annulus(21659.348600, 38716.837200, 496.660919, 993.321837, X, Y) [Wed Oct 5 04:14:37 2011] Writing fullrun_pn_xmm0112551201_pi300-10000_pass1_cl_src8.gif [Wed Oct 5 04:19:22 2011] Mean detx,y = (-5496.38, 14198.88) [Wed Oct 5 04:19:24 2011] Setting backscal keywords in source and bgd. spectrum [Wed Oct 5 04:19:39 2011] Binned source spectrum to 10 counts/bin [Wed Oct 5 04:19:40 2011] Setting source spectrum file to fullrun_pn_xmm0112551201_pi300-10000_pass1_cl_src8_src_b10.pi.gz [Wed Oct 5 04:19:40 2011] Setting bgd. spectrum file to fullrun_pn_xmm0112551201_pi300-10000_pass1_cl_src8_bgd.pi.gz [Wed Oct 5 04:39:47 2011] Not generating rmf since there are only 40 counts [Wed Oct 5 04:39:47 2011] rmf not generated due to insufficient counts [Wed Oct 5 05:05:03 2011] Updating aperture counts using extracted products [Wed Oct 5 05:05:03 2011] Error reading totcts from fullrun_pn_xmm0112551201_pi300-10000_pass1_cl_src8_src_b10.pi.gz [Wed Oct 5 05:05:03 2011] Calculating source flux in energy range 0.30-8.00 [Wed Oct 5 05:05:03 2011] Using photon index=1.80, rate=0.00404, arf fullrun_pn_xmm0112551201_pi300-10000_pass1_cl_src8.arf [Wed Oct 5 05:05:03 2011] Assuming count rate is from the 0.30-10.00 bandpass [Wed Oct 5 05:05:03 2011] Updating source flux to 4.2e-14 [Wed Oct 5 05:05:56 2011] Source 8 has fewer than 100.000000 counts, skipping spectral fitting