skip = machinename x3.localdomain process id = 19381: smart_fit pl logroot=fullrun_pn_xmm0111970701_pi300-10000_pass1_cl_src16_pl flux_elow=0.300000 flux_ehi=8.000000 2 parameters in pl dchi = 4.605 F(2.0-10.0 keV) = 4.16e-14 Count rates: 0.01496 Entry point parameter values: Nh = 0.0309 () Gamma = 2.09 () Starting error search... Getting error on parameter #2 = Nh smart_error exited normally Hard limit reached before req. deltachisq for lower bound Nh = 0.0309 (0 - 0.229) Getting error on parameter #3 = Gamma smart_error exited normally Gamma = 2.09 (1.67 - 3.01) Saving fit as fullrun_pn_xmm0111970701_pi300-10000_pass1_cl_src16_pl_new.xcm in order to save the revised "delta" values (to improve future error search efficiency) Final chisq(dof) = 8.002(12) F(0.5-2.0 keV) = 3.731e-14 F(2.0-10.0 keV) = 4.161e-14 F(0.3-8.0) = 8.369e-14 Count rates: 0.01496