[Thu May 31 20:24:28 2012] Detection parameters: Position = (450.1, 313.2) = 12 3 50.37 -62 0 24.1 Extent = 10.9" x 10.9", rotation angle = 0 degrees Source counts = 150.6 +/- 18.9 Background counts = 59.1 Rate = 0.002 +/- 0.0003 [Thu May 31 20:24:29 2012] Off-axis axis estimate = 11.04' [Thu May 31 20:27:43 2012] Using EEF radius (= 11.95 ")to estimate initial spatial extent for simple fitting [Thu May 31 20:27:43 2012] Initial guess for spatial extent in simple fitting = 11.95" [Thu May 31 20:27:43 2012] source mask rpix=2.7, npix_max = 42, mask sum = 36, frac = 0.854 [Thu May 31 20:27:43 2012] Giving source the simple spatial ID 19 for pass 0, mean size = 11.95" [Thu May 31 21:42:41 2012] fullrun_pn_xmm0109110101_pi300-10000_cl_pass0_src19.ximg exists [Thu May 31 21:42:41 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0109110101_pi300-10000_cl_pass0_src19.csv [Thu May 31 21:42:41 2012] fullrun_pn_xmm0109110101_pi300-10000_cl_pass0_src19_1.ximg exists [Thu May 31 21:42:41 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0109110101_pi300-10000_cl_pass0_src19.csv [Thu May 31 21:42:41 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0109110101_pi300-10000_cl_pass0_src19_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0109110101_pi300-10000_cl_pass0_src19.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Thu May 31 21:42:42 2012] fullrun_pn_xmm0109110101_pi300-10000_cl_pass0_tfrozen_src19.ximg exists [Thu May 31 21:42:42 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0109110101_pi300-10000_cl_pass0_tfrozen_src19.csv [Thu May 31 21:42:42 2012] fullrun_pn_xmm0109110101_pi300-10000_cl_pass0_tfrozen_src19_1.ximg exists [Thu May 31 21:42:42 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0109110101_pi300-10000_cl_pass0_tfrozen_src19.csv [Thu May 31 21:42:42 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0109110101_pi300-10000_cl_pass0_tfrozen_src19_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0109110101_pi300-10000_cl_pass0_tfrozen_src19.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Thu May 31 23:18:36 2012] Warning, spatial fit 19 centroid is now closest to src. 17 [Thu May 31 23:18:37 2012] Vigneting correction estimate = 1.000000 [Thu May 31 23:18:37 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Thu May 31 23:18:37 2012] Assessing source extent using major [Thu May 31 23:18:37 2012] Source does appear to be extended [Thu May 31 23:18:37 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Thu May 31 23:19:02 2012] Using EEF radius (= 11.95 ")to estimate initial spatial extent for simple fitting [Thu May 31 23:19:02 2012] Initial guess for spatial extent in simple fitting = 11.95" [Thu May 31 23:19:02 2012] source mask rpix=2.7, npix_max = 42, mask sum = 36, frac = 0.854 [Thu May 31 23:19:02 2012] Giving source the simple spatial ID 18 for pass 1, mean size = 11.95" [Fri Jun 1 00:34:59 2012] fullrun_pn_xmm0109110101_pi300-10000_cl_pass1_src18.ximg exists [Fri Jun 1 00:34:59 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0109110101_pi300-10000_cl_pass1_src18.csv [Fri Jun 1 00:34:59 2012] fullrun_pn_xmm0109110101_pi300-10000_cl_pass1_src18_1.ximg exists [Fri Jun 1 00:34:59 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0109110101_pi300-10000_cl_pass1_src18.csv [Fri Jun 1 00:34:59 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0109110101_pi300-10000_cl_pass1_src18_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0109110101_pi300-10000_cl_pass1_src18.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Fri Jun 1 00:35:00 2012] fullrun_pn_xmm0109110101_pi300-10000_cl_pass1_tfrozen_src18.ximg exists [Fri Jun 1 00:35:00 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0109110101_pi300-10000_cl_pass1_tfrozen_src18.csv [Fri Jun 1 00:35:00 2012] fullrun_pn_xmm0109110101_pi300-10000_cl_pass1_tfrozen_src18_1.ximg exists [Fri Jun 1 00:35:00 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0109110101_pi300-10000_cl_pass1_tfrozen_src18.csv [Fri Jun 1 00:35:00 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0109110101_pi300-10000_cl_pass1_tfrozen_src18_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0109110101_pi300-10000_cl_pass1_tfrozen_src18.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Fri Jun 1 01:51:05 2012] Warning, spatial fit 18 centroid is now closest to src. 17 [Fri Jun 1 01:51:05 2012] Vigneting correction estimate = 1.000000 [Fri Jun 1 01:51:05 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Fri Jun 1 01:51:05 2012] Assessing source extent using major [Fri Jun 1 01:51:05 2012] Source does appear to be extended [Fri Jun 1 01:51:05 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Fri Jun 1 01:51:29 2012] XMMSAS src. selection expression = ellipse(39105.984344, 27198.512482, 652.500000, 652.500000, 0.000000, X, Y) [Fri Jun 1 01:51:29 2012] Writing source region out to fullrun_pn_xmm0109110101_pi300-10000_pass1_cl_src19_src.reg [Fri Jun 1 01:51:29 2012] Extracting stamp from image fullrun_pn_xmm0109110101_pi300-10000_cl_sm2.00.img.gz, (413, 276) - (488, 351) [Fri Jun 1 01:51:29 2012] XMMSAS bgd. selection expression = annulus(39105.984344, 27198.512482, 1087.500000, 2175.000000, X, Y) && !ellipse(37170.460022, 28831.467010, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(39955.176880, 28317.750702, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(36877.479200, 27047.818400, 379.445611, 379.445611, 0.000000, X, Y) && !ellipse(36172.131836, 24913.620819, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(39103.631989, 24809.490570, 870.000000, 870.000000, 0.000000, X, Y) [Fri Jun 1 01:51:29 2012] Writing fullrun_pn_xmm0109110101_pi300-10000_pass1_cl_src19.gif [Fri Jun 1 02:03:34 2012] Mean detx,y = (-10138.53, -8134.62) [Fri Jun 1 02:03:37 2012] Setting backscal keywords in source and bgd. spectrum [Fri Jun 1 02:03:50 2012] Binned source spectrum to 10 counts/bin [Fri Jun 1 02:03:50 2012] Setting source spectrum file to fullrun_pn_xmm0109110101_pi300-10000_pass1_cl_src19_src_b10.pi.gz [Fri Jun 1 02:03:50 2012] Setting bgd. spectrum file to fullrun_pn_xmm0109110101_pi300-10000_pass1_cl_src19_bgd.pi.gz [Fri Jun 1 02:48:47 2012] Not generating rmf since RequireSpatial is true but spatial fitting not done [Fri Jun 1 02:48:47 2012] rmf not generated due to insufficient counts [Fri Jun 1 04:28:46 2012] Updating aperture counts using extracted products [Fri Jun 1 04:28:46 2012] Error reading totcts from fullrun_pn_xmm0109110101_pi300-10000_pass1_cl_src19_src_b10.pi.gz [Fri Jun 1 04:28:47 2012] Calculating source flux in energy range 0.30-8.00 [Fri Jun 1 04:28:47 2012] Using photon index=1.80, rate=0.0021, arf fullrun_pn_xmm0109110101_pi300-10000_pass1_cl_src19.arf [Fri Jun 1 04:28:47 2012] Assuming count rate is from the 0.30-10.00 bandpass [Fri Jun 1 04:28:47 2012] Updating source flux to 1.3e-14 [Fri Jun 1 04:29:59 2012] Simple spatial fitting not done (or not done successfully), skipping spectral fitting