skip = machinename x3.localdomain process id = 31853: smart_fit pl logroot=fullrun_pn_xmm0108060701_pi300-10000_pass1_cl_src47_pl flux_elow=0.300000 flux_ehi=8.000000 2 parameters in pl dchi = 4.605 F(2.0-10.0 keV) = 2.499e-15 Count rates: 0.002493 Entry point parameter values: Nh = 0.122 () Gamma = 2.72 () Starting error search... Getting error on parameter #2 = Nh smart_error exited normally Hard limit reached before req. deltachisq for lower bound Nh = 0.122 (0 - 0.529) Getting error on parameter #3 = Gamma smart_error exited normally Gamma = 2.72 (1.66 - 5.56) Saving fit as fullrun_pn_xmm0108060701_pi300-10000_pass1_cl_src47_pl_new.xcm in order to save the revised "delta" values (to improve future error search efficiency) Final chisq(dof) = 17.841(23) F(0.5-2.0 keV) = 4.107e-15 F(2.0-10.0 keV) = 2.499e-15 F(0.3-8.0) = 7.147e-15 Count rates: 0.002493