[Sat Jun 15 04:41:40 2013] Detection parameters: Position = (265.5, 374.2) = 22 28 34.33 -5 12 26.1 Extent = 10.9" x 10.9", rotation angle = 0 degrees Source counts = 193.7 +/- 17.6 Background counts = 35.7 Rate = 0.007 +/- 0.0007 [Sat Jun 15 04:41:42 2013] Off-axis axis estimate = 5.99' [Sat Jun 15 04:44:59 2013] Using EEF radius (= 9.42 ")to estimate initial spatial extent for simple fitting [Sat Jun 15 04:44:59 2013] Initial guess for spatial extent in simple fitting = 9.42" [Sat Jun 15 04:44:59 2013] source mask rpix=2.2, npix_max = 28, mask sum = 26, frac = 0.915 [Sat Jun 15 04:44:59 2013] Giving source the simple spatial ID 4 for pass 0, mean size = 9.42" [Sat Jun 15 06:49:51 2013] fullrun_pn_xmm0100440101_pi300-10000_cl_pass0_src4.ximg exists [Sat Jun 15 06:49:51 2013] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0100440101_pi300-10000_cl_pass0_src4.csv [Sat Jun 15 06:49:51 2013] fullrun_pn_xmm0100440101_pi300-10000_cl_pass0_src4_1.ximg exists [Sat Jun 15 06:49:51 2013] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0100440101_pi300-10000_cl_pass0_src4.csv [Sat Jun 15 06:49:51 2013] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0100440101_pi300-10000_cl_pass0_src4_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0100440101_pi300-10000_cl_pass0_src4.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Sat Jun 15 06:49:52 2013] fullrun_pn_xmm0100440101_pi300-10000_cl_pass0_tfrozen_src4.ximg exists [Sat Jun 15 06:49:52 2013] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0100440101_pi300-10000_cl_pass0_tfrozen_src4.csv [Sat Jun 15 06:49:52 2013] fullrun_pn_xmm0100440101_pi300-10000_cl_pass0_tfrozen_src4_1.ximg exists [Sat Jun 15 06:49:52 2013] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0100440101_pi300-10000_cl_pass0_tfrozen_src4.csv [Sat Jun 15 06:49:52 2013] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0100440101_pi300-10000_cl_pass0_tfrozen_src4_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0100440101_pi300-10000_cl_pass0_tfrozen_src4.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Sat Jun 15 08:54:19 2013] Warning: source 4 in spatial fitting list does not appear to have a counterpart in memory, closest src. was src. 5 at 11.308397 pixels away [Sat Jun 15 08:54:20 2013] Vigneting correction estimate = 1.000000 [Sat Jun 15 08:54:20 2013] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Sat Jun 15 08:54:20 2013] Assessing source extent using major [Sat Jun 15 08:54:20 2013] Source does appear to be extended [Sat Jun 15 08:54:20 2013] Computing asymmetry using major and minor axis, asym = 1.00 [Sat Jun 15 08:54:52 2013] Using EEF radius (= 9.42 ")to estimate initial spatial extent for simple fitting [Sat Jun 15 08:54:52 2013] Initial guess for spatial extent in simple fitting = 9.42" [Sat Jun 15 08:54:52 2013] source mask rpix=2.2, npix_max = 28, mask sum = 26, frac = 0.915 [Sat Jun 15 08:54:52 2013] Giving source the simple spatial ID 4 for pass 1, mean size = 9.42" [Sat Jun 15 10:58:06 2013] fullrun_pn_xmm0100440101_pi300-10000_cl_pass1_src4.ximg exists [Sat Jun 15 10:58:06 2013] fullrun_pn_xmm0100440101_pi300-10000_cl_pass1_src4_1.ximg exists [Sat Jun 15 10:58:06 2013] Fit fullrun_pn_xmm0100440101_pi300-10000_cl_pass1_src4 appears to have run properly [Sat Jun 15 10:58:07 2013] fullrun_pn_xmm0100440101_pi300-10000_cl_pass1_tfrozen_src4.ximg exists [Sat Jun 15 10:58:07 2013] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0100440101_pi300-10000_cl_pass1_tfrozen_src4.csv [Sat Jun 15 10:58:07 2013] fullrun_pn_xmm0100440101_pi300-10000_cl_pass1_tfrozen_src4_1.ximg exists [Sat Jun 15 10:58:07 2013] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0100440101_pi300-10000_cl_pass1_tfrozen_src4.csv [Sat Jun 15 10:58:07 2013] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0100440101_pi300-10000_cl_pass1_tfrozen_src4_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0100440101_pi300-10000_cl_pass1_tfrozen_src4.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Sat Jun 15 12:53:49 2013] Spatial fit model total counts = 522.476000, observed total counts = 479.000000 [Sat Jun 15 12:53:49 2013] Offset between fit and detection position for source 5 = 0.306814 pixels [Sat Jun 15 12:53:49 2013] 511.767000 total counts/ 374.126000 bgd. counts: snr = 7.116048 Spatial fit parameters: Offset between fit and detection position for source 5 = 0.306814 pixels Position = (265.2, 374.1) = 22 28 34.42 -5 12 26.3 Extent = 5.0 (3.9-6.6)" x 4.6 (3.8-6.0)", rotation angle = 77 (50-90) degrees Source counts = 137.6 +/- 22.6 Background counts = 374.1 Rate = 0.003 +/- 0.0005 [Sat Jun 15 12:53:53 2013] Vigneting correction estimate = 1.000000 [Sat Jun 15 12:53:53 2013] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Sat Jun 15 12:53:53 2013] Assessing source extent using major axis lower bound [Sat Jun 15 12:53:53 2013] Source does appear to be extended [Sat Jun 15 12:53:53 2013] Computing asymmetry using errors on major and minor axis (from spatial fitting), asym = 0.64 [Sat Jun 15 12:54:26 2013] XMMSAS src. selection expression = ellipse(23023.629580, 32499.702800, 300.121209, 278.573408, 76.727572, X, Y) [Sat Jun 15 12:54:26 2013] Writing source region out to fullrun_pn_xmm0100440101_pi300-10000_pass1_cl_src5_src.reg [Sat Jun 15 12:54:26 2013] Extracting stamp from image fullrun_pn_xmm0100440101_pi300-10000_cl_sm2.00.img.gz, (248, 357) - (282, 391) [Sat Jun 15 12:54:26 2013] XMMSAS bgd. selection expression = annulus(23023.629580, 32499.702800, 500.202014, 1000.404029, X, Y) && !ellipse(21320.115662, 32306.061371, 870.000000, 870.000000, 0.000000, X, Y) [Sat Jun 15 12:54:26 2013] Writing fullrun_pn_xmm0100440101_pi300-10000_pass1_cl_src5.gif [Sat Jun 15 12:57:49 2013] Mean detx,y = (3881.25, 6692.93) [Sat Jun 15 12:57:53 2013] Setting backscal keywords in source and bgd. spectrum [Sat Jun 15 12:58:10 2013] Binned source spectrum to 10 counts/bin [Sat Jun 15 12:58:10 2013] Setting source spectrum file to fullrun_pn_xmm0100440101_pi300-10000_pass1_cl_src5_src_b10.pi.gz [Sat Jun 15 12:58:10 2013] Setting bgd. spectrum file to fullrun_pn_xmm0100440101_pi300-10000_pass1_cl_src5_bgd.pi.gz [Sat Jun 15 15:47:28 2013] Updating aperture counts using extracted products [Sat Jun 15 15:47:28 2013] Total counts from fullrun_pn_xmm0100440101_pi300-10000_pass1_cl_src5_src_b10.pi.gz = 196.00 [Sat Jun 15 15:47:28 2013] Total counts from fullrun_pn_xmm0100440101_pi300-10000_pass1_cl_src5_bgd.pi.gz = 360.00 [Sat Jun 15 15:47:28 2013] Got source and background scale factors 248766.000000, 1689023.000000 [Sat Jun 15 15:47:28 2013] User source parameters: Position = (265.2, 374.1) = 22 28 34.42 -5 12 26.3 Extent = 5.0 (3.9-6.6)" x 4.6 (3.8-6.0)", rotation angle = 77 (50-90) degrees Source aperture counts = 143.0 +/- 15.0 Background aperture counts = 53.0 Rate = 0.003 +/- 0.0003 [Sat Jun 15 15:47:42 2013] Calculating source flux in energy range 0.30-8.00 [Sat Jun 15 15:47:42 2013] Using photon index=1.80, rate=0.00318, arf fullrun_pn_xmm0100440101_pi300-10000_pass1_cl_src5.arf [Sat Jun 15 15:47:42 2013] Assuming count rate is from the 0.30-10.00 bandpass [Sat Jun 15 15:47:42 2013] Updating source flux to 2e-14 [Sat Jun 15 15:48:13 2013] xmm0100440101/analysis//spectral/fullrun_pn_xmm0100440101_pi300-10000_pass1_cl_src5_pl.csv not found, spectral fit skipped or did not complete