skip = machinename x3.localdomain process id = 3158: smart_fit pl logroot=fullrun_mos2_xmm0098610201_pi300-10000_pass1_cl_src12_pl flux_elow=0.300000 flux_ehi=8.000000 2 parameters in pl dchi = 4.605 F(2.0-10.0 keV) = 1.569e-12 Count rates: 0.01126 Entry point parameter values: Nh = 4.11 () Gamma = 1.32 () Starting error search... Getting error on parameter #2 = Nh smart_error exited normally Nh = 4.11 (2.5 - 6.67) Getting error on parameter #3 = Gamma smart_error exited normally Gamma = 1.32 (0.642 - 2.17) Saving fit as fullrun_mos2_xmm0098610201_pi300-10000_pass1_cl_src12_pl_new.xcm in order to save the revised "delta" values (to improve future error search efficiency) Final chisq(dof) = 121.996(112) F(0.5-2.0 keV) = 1.838e-14 F(2.0-10.0 keV) = 1.569e-12 F(0.3-8.0) = 1.188e-12 Count rates: 0.01126