skip = machinename x3.localdomain process id = 29643: smart_fit pl logroot=fullrun_mos1_xmm0098610201_pi300-10000_pass1_cl_src6_pl flux_elow=0.300000 flux_ehi=8.000000 2 parameters in pl dchi = 4.605 F(2.0-10.0 keV) = 4.865e-11 Count rates: 1.711 Entry point parameter values: Nh = 9.53 () Gamma = 2.8 () Starting error search... Getting error on parameter #2 = Nh smart_error exited normally Nh = 9.53 (9.35 - 9.7) Getting error on parameter #3 = Gamma smart_error exited normally Gamma = 2.8 (2.75 - 2.85) Saving fit as fullrun_mos1_xmm0098610201_pi300-10000_pass1_cl_src6_pl_new.xcm in order to save the revised "delta" values (to improve future error search efficiency) Final chisq(dof) = 912.794(578) F(0.5-2.0 keV) = 1.998e-13 F(2.0-10.0 keV) = 4.865e-11 F(0.3-8.0) = 4.15e-11 Count rates: 1.711