Source List

Observation details report
Detailed source parameters (including errors) in a comma-separated values file

Click on source number for detailed analysis, including spectral fits if applicable

data idnum idradec telescope instrument x y cnts cntserr rate rateerr SNR poisprob sigmaj sigmin incang offax cnts_soft cnts_hard hr hr_err ext var N_H flux vign flags
Report srcpi bgdpi 1 X110337.67-232929.9 xmm pn 304.571 321.557 72571.8 313.324 11.3776 0.0491222 453.574 1 5.80131 5.7303 325.866 1.74978 F T 3.07991 0 1 ds
Report srcpi bgdpi 1 X110337.60-232930.2 xmm mos2 304.794 321.693 8540.14 109.227 3.21514 0.041121 0 10.875 10.875 0 1.74796 F T 3.07958 0 1 db
Report srcpi bgdpi 1 X110337.64-232930.1 xmm mos1 304.674 321.528 2587.18 57.8982 4.30733 0.0963933 93.5387 1 5.52514 5.52514 0 1.71961 F T 3.07966 0 1 ds

counts and rate are bgd.-subtracted, based on simple spatial fitting (if done) or extracted counts from aperture otherwise (N.B., in either case aperture counts are given csv file).
cntserr, rateerr = Error on (source) counts and count rate, based on error in total counts
SNR = signal-to-noise ratio, computed using Nsrc/sqrt(Nbgd)
poisprob = Poisson probability of observing total counts given bgd. counts
sigmaj, sigmin = source extent (from detection output or spatial fitting) in units of arcsecs.
incang = position angle of source (inclination from x-axis)
cnts_soft = bgd.-subtracted counts in soft band (0.50 - 2.00 KeV, always taken directly from source aperture rather than model fitting)
cnts_hard = bgd.-subtracted counts in hard band (2.00 - 10.00 KeV, always taken directly from source aperture rather than model fitting)
hr, hr_err = hardness ratio ([cnts_hard-cnts_soft]/[cnts_hard+cnts_soft]) and error
ext = source extension flag: F = false (not extended), A = true (extended), A = asymetric (ratio of sigmaj/sigmin > 1 + x, where x = 0.5 by default)
var = variability flag: U = unknown, F = false (is not variable), T = true
N_H = Galactic column density as determined from LHEASOFT nh program
flux = flux determined from count rate using pimms (in the 0.30-8.00 keV bandpass for a power-law model with ph. index = 1.8)
vign = vignetting correction
Flags: d = detection parameters, s = simple spatial fitting parameters, b = simple spatial fitting failed, p = poor simple spatial fit, x = extracted events parameters, t = temporal anaylsis parameters, i = psf spatial fitting parameters, f = spectral fitting parameters, c = source is confused, u = user-defined source, v = detected source coincident with user-defined source, r = source is in region-of-interest