[Wed Apr 11 06:33:02 2012] Detection parameters: Position = (278.1, 315.7) = 3 39 50.05 -35 25 2.9 Extent = 10.9" x 10.9", rotation angle = 0 degrees Source counts = 64.8 +/- 13.3 Background counts = 42.8 Rate = 0.001 +/- 0.0003 [Wed Apr 11 06:33:02 2012] Off-axis axis estimate = 1.94' [Wed Apr 11 06:33:34 2012] Using EEF radius (= 7.40 ")to estimate initial spatial extent for simple fitting [Wed Apr 11 06:33:34 2012] Initial guess for spatial extent in simple fitting = 7.40" [Wed Apr 11 06:33:34 2012] source mask rpix=1.7, npix_max = 19, mask sum = 16, frac = 0.826 [Wed Apr 11 06:33:34 2012] Giving source the simple spatial ID 41 for pass 0, mean size = 7.40" [Wed Apr 11 06:33:34 2012] fullrun_mos2_xmm0055140101_pi300-10000_cl_pass0_src41.ximg exists [Wed Apr 11 06:33:34 2012] fullrun_mos2_xmm0055140101_pi300-10000_cl_pass0_src41_1.ximg exists [Wed Apr 11 06:33:34 2012] Fit fullrun_mos2_xmm0055140101_pi300-10000_cl_pass0_src41 appears to have run properly [Wed Apr 11 06:33:35 2012] fullrun_mos2_xmm0055140101_pi300-10000_cl_pass0_tfrozen_src41.ximg exists [Wed Apr 11 06:33:35 2012] fullrun_mos2_xmm0055140101_pi300-10000_cl_pass0_tfrozen_src41_1.ximg exists [Wed Apr 11 06:33:35 2012] Fit fullrun_mos2_xmm0055140101_pi300-10000_cl_pass0_tfrozen_src41 appears to have run properly [Wed Apr 11 06:33:56 2012] Warning, spatial fit 41 centroid is now closest to src. 34 [Wed Apr 11 06:33:56 2012] Vigneting correction estimate = 1.000000 [Wed Apr 11 06:33:56 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Wed Apr 11 06:33:56 2012] Assessing source extent using major [Wed Apr 11 06:33:56 2012] Source does appear to be extended [Wed Apr 11 06:33:56 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Wed Apr 11 06:34:15 2012] Using EEF radius (= 7.40 ")to estimate initial spatial extent for simple fitting [Wed Apr 11 06:34:15 2012] Initial guess for spatial extent in simple fitting = 7.40" [Wed Apr 11 06:34:15 2012] source mask rpix=1.7, npix_max = 19, mask sum = 16, frac = 0.826 [Wed Apr 11 06:34:15 2012] Giving source the simple spatial ID 41 for pass 1, mean size = 7.40" [Wed Apr 11 06:34:16 2012] fullrun_mos2_xmm0055140101_pi300-10000_cl_pass1_src41.ximg exists [Wed Apr 11 06:34:16 2012] Warning: model total counts is not > 0 in csv/fullrun_mos2_xmm0055140101_pi300-10000_cl_pass1_src41.csv [Wed Apr 11 06:34:16 2012] fullrun_mos2_xmm0055140101_pi300-10000_cl_pass1_src41_1.ximg exists [Wed Apr 11 06:34:16 2012] Warning: model total counts is not > 0 in csv/fullrun_mos2_xmm0055140101_pi300-10000_cl_pass1_src41.csv [Wed Apr 11 06:34:16 2012] It looks like the fit did not converge You should probably delete fullrun_mos2_xmm0055140101_pi300-10000_cl_pass1_src41_1.ximg Either tweak this fit manually starting from fullrun_mos2_xmm0055140101_pi300-10000_cl_pass1_src41.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Wed Apr 11 06:34:17 2012] fullrun_mos2_xmm0055140101_pi300-10000_cl_pass1_tfrozen_src41.ximg exists [Wed Apr 11 06:34:17 2012] fullrun_mos2_xmm0055140101_pi300-10000_cl_pass1_tfrozen_src41_1.ximg exists [Wed Apr 11 06:34:17 2012] Fit fullrun_mos2_xmm0055140101_pi300-10000_cl_pass1_tfrozen_src41 appears to have run properly [Wed Apr 11 06:34:36 2012] Warning: source 25 in spatial fitting list does not appear to have a counterpart in memory, closest src. was src. 32 at 28.199498 pixels away [Wed Apr 11 06:34:36 2012] Warning: source 38 in spatial fitting list does not appear to have a counterpart in memory, closest src. was src. 32 at 32.814499 pixels away [Wed Apr 11 06:34:36 2012] Warning, spatial fit 41 centroid is now closest to src. 34 [Wed Apr 11 06:34:36 2012] Vigneting correction estimate = 1.000000 [Wed Apr 11 06:34:36 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Wed Apr 11 06:34:36 2012] Assessing source extent using major [Wed Apr 11 06:34:36 2012] Source does appear to be extended [Wed Apr 11 06:34:36 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Wed Apr 11 07:33:25 2012] XMMSAS src. selection expression = ellipse(24143.126007, 27417.727631, 652.500000, 652.500000, 0.000000, X, Y) [Wed Apr 11 07:33:25 2012] Writing source region out to fullrun_mos2_xmm0055140101_pi300-10000_pass1_cl_src32_src.reg [Wed Apr 11 07:33:25 2012] Extracting stamp from image fullrun_mos2_xmm0055140101_pi300-10000_cl_sm2.00.img.gz, (241, 278) - (316, 353) [Wed Apr 11 07:33:25 2012] XMMSAS bgd. selection expression = annulus(24143.126007, 27417.727631, 1087.500000, 2175.000000, X, Y) && !ellipse(25894.002700, 28480.798800, 364.280810, 364.280810, 0.000000, X, Y) && !ellipse(24320.334400, 28932.799860, 1255.928036, 1255.928036, 0.000000, X, Y) [Wed Apr 11 07:33:25 2012] Writing fullrun_mos2_xmm0055140101_pi300-10000_pass1_cl_src32.gif [Wed Apr 11 07:52:33 2012] Mean detx,y = (3473.26, -1596.22) [Wed Apr 11 07:52:34 2012] Setting backscal keywords in source and bgd. spectrum [Wed Apr 11 07:52:38 2012] Binned source spectrum to 10 counts/bin [Wed Apr 11 07:52:39 2012] Setting source spectrum file to fullrun_mos2_xmm0055140101_pi300-10000_pass1_cl_src32_src_b10.pi.gz [Wed Apr 11 07:52:39 2012] Setting bgd. spectrum file to fullrun_mos2_xmm0055140101_pi300-10000_pass1_cl_src32_bgd.pi.gz [Wed Apr 11 08:35:53 2012] Not generating rmf since there are only 64 counts [Wed Apr 11 08:35:53 2012] rmf not generated due to insufficient counts [Wed Apr 11 08:36:51 2012] Updating aperture counts using extracted products [Wed Apr 11 08:36:51 2012] Error reading totcts from fullrun_mos2_xmm0055140101_pi300-10000_pass1_cl_src32_src_b10.pi.gz [Wed Apr 11 08:36:52 2012] Calculating source flux in energy range 0.30-8.00 [Wed Apr 11 08:36:52 2012] Using photon index=1.80, rate=0.00149, arf fullrun_mos2_xmm0055140101_pi300-10000_pass1_cl_src32.arf [Wed Apr 11 08:36:52 2012] Assuming count rate is from the 0.30-10.00 bandpass [Wed Apr 11 08:36:52 2012] Updating source flux to 1.5e-14 [Wed Apr 11 08:39:11 2012] Simple spatial fitting not done (or not done successfully), skipping spectral fitting