[Fri Jul 13 08:04:43 2012] Detection parameters: Position = (303.0, 319.0) = 16 28 38.22 39 33 3.6 Extent = 10.9" x 10.9", rotation angle = 0 degrees Source counts = 7243.3 +/- 110.0 Background counts = 380.0 Rate = 1 +/- 0.02 [Fri Jul 13 08:04:44 2012] Off-axis axis estimate = 1.53' [Fri Jul 13 08:07:13 2012] Using EEF radius (= 7.19 ")to estimate initial spatial extent for simple fitting [Fri Jul 13 08:07:13 2012] Initial guess for spatial extent in simple fitting = 7.19" [Fri Jul 13 08:07:13 2012] source mask rpix=1.7, npix_max = 18, mask sum = 16, frac = 0.863 [Fri Jul 13 08:07:13 2012] Giving source the simple spatial ID 1 for pass 0, mean size = 7.19" [Fri Jul 13 12:28:00 2012] fullrun_pn_xmm0008030601_pi300-10000_cl_pass0_src1.ximg exists [Fri Jul 13 12:28:00 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0008030601_pi300-10000_cl_pass0_src1.csv [Fri Jul 13 12:28:00 2012] fullrun_pn_xmm0008030601_pi300-10000_cl_pass0_src1_1.ximg exists [Fri Jul 13 12:28:00 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0008030601_pi300-10000_cl_pass0_src1.csv [Fri Jul 13 12:28:00 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0008030601_pi300-10000_cl_pass0_src1_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0008030601_pi300-10000_cl_pass0_src1.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Fri Jul 13 12:28:01 2012] fullrun_pn_xmm0008030601_pi300-10000_cl_pass0_tfrozen_src1.ximg exists [Fri Jul 13 12:28:01 2012] fullrun_pn_xmm0008030601_pi300-10000_cl_pass0_tfrozen_src1_1.ximg exists [Fri Jul 13 12:28:01 2012] Fit fullrun_pn_xmm0008030601_pi300-10000_cl_pass0_tfrozen_src1 appears to have run properly [Fri Jul 13 15:48:16 2012] Spatial fit model total counts = 25170.500000, observed total counts = 25111.000000 [Fri Jul 13 15:48:16 2012] Offset between fit and detection position for source 1 = 0.113320 pixels [Fri Jul 13 15:48:16 2012] 25191.850000 total counts/ 18291.500000 bgd. counts: snr = 51.020705 Spatial fit parameters: Offset between fit and detection position for source 1 = 0.113320 pixels Position = (303.0, 319.1) = 16 28 38.20 39 33 3.2 Extent = 13.4 (12.6-14.3)", rotation angle = 0 Source counts = 6900.4 +/- 158.7 Background counts = 18291.5 Rate = 1 +/- 0.03 [Fri Jul 13 15:48:16 2012] Vigneting correction estimate = 1.000000 [Fri Jul 13 15:48:16 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Fri Jul 13 15:48:16 2012] Assessing source extent using major axis lower bound [Fri Jul 13 15:48:16 2012] Source does appear to be extended [Fri Jul 13 15:48:16 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Fri Jul 13 15:48:38 2012] Using previous fit value to estimate initial spatial extent for simple fitting [Fri Jul 13 15:48:38 2012] Setting initial spatial extent for simple fitting to maximum allowed for this pass [Fri Jul 13 15:48:38 2012] Initial guess for spatial extent in simple fitting = 13.43" [Fri Jul 13 15:48:38 2012] source mask rpix=3.1, npix_max = 51, mask sum = 56, frac = 1.087 [Fri Jul 13 15:48:38 2012] Giving source the simple spatial ID 1 for pass 1, mean size = 13.43" [Fri Jul 13 17:39:54 2012] fullrun_pn_xmm0008030601_pi300-10000_cl_pass1_src1.ximg exists [Fri Jul 13 17:39:54 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0008030601_pi300-10000_cl_pass1_src1.csv [Fri Jul 13 17:39:54 2012] fullrun_pn_xmm0008030601_pi300-10000_cl_pass1_src1_1.ximg exists [Fri Jul 13 17:39:54 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0008030601_pi300-10000_cl_pass1_src1.csv [Fri Jul 13 17:39:54 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0008030601_pi300-10000_cl_pass1_src1_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0008030601_pi300-10000_cl_pass1_src1.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Fri Jul 13 17:39:54 2012] fullrun_pn_xmm0008030601_pi300-10000_cl_pass1_tfrozen_src1.ximg exists [Fri Jul 13 17:39:54 2012] Warning: model total counts is not > 0 in csv/fullrun_pn_xmm0008030601_pi300-10000_cl_pass1_tfrozen_src1.csv [Fri Jul 13 17:39:54 2012] fullrun_pn_xmm0008030601_pi300-10000_cl_pass1_tfrozen_src1_1.ximg exists [Fri Jul 13 17:39:54 2012] Warning: model total counts is not > 0 in csv/fullrun_pn_xmm0008030601_pi300-10000_cl_pass1_tfrozen_src1.csv [Fri Jul 13 17:39:54 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0008030601_pi300-10000_cl_pass1_tfrozen_src1_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0008030601_pi300-10000_cl_pass1_tfrozen_src1.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Fri Jul 13 20:54:11 2012] Warning, spatial fit 1 centroid is now closest to src. 18 [Fri Jul 13 20:54:11 2012] Vigneting correction estimate = 1.000000 [Fri Jul 13 20:54:11 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Fri Jul 13 20:54:11 2012] Assessing source extent using major axis lower bound [Fri Jul 13 20:54:11 2012] Source does appear to be extended [Fri Jul 13 20:54:11 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Fri Jul 13 20:54:11 2012] Source is confused with source 2 [Fri Jul 13 20:54:29 2012] Counts = 6900.350000, rescaling region sizes by 2.000000 [Fri Jul 13 20:54:29 2012] XMMSAS src. selection expression = ellipse(26313.109290, 27712.605600, 1612.008046, 1612.008046, 0.000000, X, Y) [Fri Jul 13 20:54:29 2012] Writing source region out to fullrun_pn_xmm0008030601_pi300-10000_pass1_cl_src1_src.reg [Fri Jul 13 20:54:29 2012] Extracting stamp from image fullrun_pn_xmm0008030601_pi300-10000_cl_sm2.00.img.gz, (210, 226) - (396, 412) [Fri Jul 13 20:54:29 2012] XMMSAS bgd. selection expression = annulus(26313.109290, 27712.605600, 5373.360155, 10746.720309, X, Y) && !ellipse(27049.038000, 26802.652000, 2360.776068, 2360.776068, 0.000000, X, Y) && !ellipse(25552.136780, 28939.343506, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(27768.474000, 26019.550000, 1184.720034, 1184.720034, 0.000000, X, Y) && !ellipse(27127.045000, 29818.324000, 731.308821, 731.308821, 0.000000, X, Y) && !ellipse(26534.964905, 29955.396667, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(23935.242000, 30143.192000, 1295.280037, 1295.280037, 0.000000, X, Y) && !ellipse(28760.381256, 27700.236023, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(28628.848450, 27013.018860, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(24093.997345, 27005.106873, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(28721.214264, 25794.968414, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(26769.285800, 25634.242000, 2392.000069, 2392.000069, 0.000000, X, Y) && !ellipse(27725.270294, 24747.081451, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(26675.298000, 24387.498000, 1196.000034, 1196.000034, 0.000000, X, Y) && !ellipse(27912.075500, 29793.479706, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(29033.376678, 28133.810272, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(19696.505508, 27247.083588, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(24528.994690, 25706.141754, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(26329.675385, 24755.211151, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(28131.386230, 24752.736664, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(22353.410200, 37112.802800, 1110.632032, 1110.632032, 0.000000, X, Y) && !ellipse(26601.837128, 30830.244751, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(27763.662000, 31017.688000, 1340.352039, 1340.352039, 0.000000, X, Y) && !ellipse(27466.866000, 23345.472000, 1196.000034, 1196.000034, 0.000000, X, Y) && !ellipse(29502.605316, 25603.612488, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(29066.506134, 24918.012238, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(26103.289001, 23961.986633, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(28107.159088, 23802.714081, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(27115.957001, 23709.602203, 870.000000, 870.000000, 0.000000, X, Y) [Fri Jul 13 20:54:29 2012] Writing fullrun_pn_xmm0008030601_pi300-10000_pass1_cl_src1.gif [Fri Jul 13 20:54:44 2012] Mean detx,y = (-103.03, -3.55) [Fri Jul 13 20:54:48 2012] Setting backscal keywords in source and bgd. spectrum [Fri Jul 13 20:58:11 2012] Binned source spectrum to 10 counts/bin [Fri Jul 13 20:58:11 2012] Setting source spectrum file to fullrun_pn_xmm0008030601_pi300-10000_pass1_cl_src1_src_b10.pi.gz [Fri Jul 13 20:58:11 2012] Setting bgd. spectrum file to fullrun_pn_xmm0008030601_pi300-10000_pass1_cl_src1_bgd.pi.gz [Sat Jul 14 16:01:42 2012] Updating aperture counts using extracted products [Sat Jul 14 16:01:42 2012] Error reading totcts from fullrun_pn_xmm0008030601_pi300-10000_pass1_cl_src1_src_b10.pi.gz [Sat Jul 14 16:01:42 2012] Calculating source flux in energy range 0.30-8.00 [Sat Jul 14 16:01:42 2012] Using photon index=1.80, rate=1.1, arf fullrun_pn_xmm0008030601_pi300-10000_pass1_cl_src1.arf [Sat Jul 14 16:01:42 2012] Assuming count rate is from the 0.30-10.00 bandpass [Sat Jul 14 16:01:42 2012] Updating source flux to 2.4e-12 [Sat Jul 14 16:05:08 2012] Flag c found in src. 1 procflags, skipping spectral fitting [Sat Jul 14 16:06:48 2012] Reading fit data from xmm0008030601/analysis//spectral/fullrun_pn_xmm0008030601_pi300-10000_pass1_cl_src1_pl.csv [Sat Jul 14 16:06:48 2012] Spectral fit parameter nH value = 1.09576e+21 [Sat Jul 14 16:06:48 2012] Spectral fit parameter PhoIndex value = 2.22938 [Sat Jul 14 16:06:48 2012] Failed to get F(0.3-8.0) from xmm0008030601/analysis//spectral/fullrun_pn_xmm0008030601_pi300-10000_pass1_cl_src1_pl.csv, possibly due to different flux energy range selected [Sat Jul 14 16:06:48 2012] Calculating source flux in energy range 0.30-8.00 [Sat Jul 14 16:06:48 2012] Using Nh = 1.1e+21, photon index=2.23, rate=1.1, arf fullrun_pn_xmm0008030601_pi300-10000_pass1_cl_src1.arf [Sat Jul 14 16:06:48 2012] Assuming count rate is from the 0.30-10.00 bandpass [Sat Jul 14 16:06:48 2012] Updating source flux to 2.4e-12