[Tue Jul 24 02:54:29 2012] Detection parameters: Position = (201.2, 345.8) = 14 1 37.42 -60 49 43.8 Extent = 10.9" x 10.9", rotation angle = 0 degrees Source counts = 89.6 +/- 13.5 Background counts = 38.4 Rate = 0.01 +/- 0.002 [Tue Jul 24 02:54:29 2012] Off-axis axis estimate = 7.84' [Tue Jul 24 02:55:40 2012] Using EEF radius (= 10.35 ")to estimate initial spatial extent for simple fitting [Tue Jul 24 02:55:40 2012] Initial guess for spatial extent in simple fitting = 10.35" [Tue Jul 24 02:55:40 2012] source mask rpix=2.4, npix_max = 33, mask sum = 21, frac = 0.633 [Tue Jul 24 02:55:40 2012] Giving source the simple spatial ID 3 for pass 0, mean size = 10.35" [Tue Jul 24 03:01:40 2012] fullrun_pn_xmm0007421901_pi300-10000_cl_pass0_src3.ximg exists [Tue Jul 24 03:01:40 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0007421901_pi300-10000_cl_pass0_src3.csv [Tue Jul 24 03:01:40 2012] fullrun_pn_xmm0007421901_pi300-10000_cl_pass0_src3_1.ximg exists [Tue Jul 24 03:01:40 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0007421901_pi300-10000_cl_pass0_src3.csv [Tue Jul 24 03:01:40 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0007421901_pi300-10000_cl_pass0_src3_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0007421901_pi300-10000_cl_pass0_src3.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Tue Jul 24 03:01:40 2012] fullrun_pn_xmm0007421901_pi300-10000_cl_pass0_tfrozen_src3.ximg exists [Tue Jul 24 03:01:40 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0007421901_pi300-10000_cl_pass0_tfrozen_src3.csv [Tue Jul 24 03:01:40 2012] fullrun_pn_xmm0007421901_pi300-10000_cl_pass0_tfrozen_src3_1.ximg exists [Tue Jul 24 03:01:40 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0007421901_pi300-10000_cl_pass0_tfrozen_src3.csv [Tue Jul 24 03:01:40 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0007421901_pi300-10000_cl_pass0_tfrozen_src3_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0007421901_pi300-10000_cl_pass0_tfrozen_src3.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Tue Jul 24 03:10:26 2012] Warning: source 3 in spatial fitting list does not appear to have a counterpart in memory, closest src. was src. 3 at 13.507714 pixels away [Tue Jul 24 03:10:26 2012] Vigneting correction estimate = 1.000000 [Tue Jul 24 03:10:26 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Jul 24 03:10:26 2012] Assessing source extent using major [Tue Jul 24 03:10:26 2012] Source does appear to be extended [Tue Jul 24 03:10:26 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Tue Jul 24 03:10:32 2012] Using EEF radius (= 10.35 ")to estimate initial spatial extent for simple fitting [Tue Jul 24 03:10:32 2012] Initial guess for spatial extent in simple fitting = 10.35" [Tue Jul 24 03:10:32 2012] source mask rpix=2.4, npix_max = 33, mask sum = 21, frac = 0.633 [Tue Jul 24 03:10:32 2012] Giving source the simple spatial ID 3 for pass 1, mean size = 10.35" [Tue Jul 24 03:17:00 2012] fullrun_pn_xmm0007421901_pi300-10000_cl_pass1_src3.ximg exists [Tue Jul 24 03:17:00 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0007421901_pi300-10000_cl_pass1_src3.csv [Tue Jul 24 03:17:00 2012] fullrun_pn_xmm0007421901_pi300-10000_cl_pass1_src3_1.ximg exists [Tue Jul 24 03:17:00 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0007421901_pi300-10000_cl_pass1_src3.csv [Tue Jul 24 03:17:00 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0007421901_pi300-10000_cl_pass1_src3_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0007421901_pi300-10000_cl_pass1_src3.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Tue Jul 24 03:17:00 2012] fullrun_pn_xmm0007421901_pi300-10000_cl_pass1_tfrozen_src3.ximg exists [Tue Jul 24 03:17:00 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0007421901_pi300-10000_cl_pass1_tfrozen_src3.csv [Tue Jul 24 03:17:00 2012] fullrun_pn_xmm0007421901_pi300-10000_cl_pass1_tfrozen_src3_1.ximg exists [Tue Jul 24 03:17:00 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0007421901_pi300-10000_cl_pass1_tfrozen_src3.csv [Tue Jul 24 03:17:00 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0007421901_pi300-10000_cl_pass1_tfrozen_src3_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0007421901_pi300-10000_cl_pass1_tfrozen_src3.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Tue Jul 24 03:25:25 2012] Warning: source 2 in spatial fitting list does not appear to have a counterpart in memory, closest src. was src. 3 at 192.247918 pixels away [Tue Jul 24 03:25:25 2012] Warning: source 3 in spatial fitting list does not appear to have a counterpart in memory, closest src. was src. 3 at 13.507714 pixels away [Tue Jul 24 03:25:25 2012] Vigneting correction estimate = 1.000000 [Tue Jul 24 03:25:25 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Jul 24 03:25:25 2012] Assessing source extent using major [Tue Jul 24 03:25:25 2012] Source does appear to be extended [Tue Jul 24 03:25:25 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Tue Jul 24 03:25:33 2012] XMMSAS src. selection expression = ellipse(17452.310135, 30034.126251, 652.500000, 652.500000, 0.000000, X, Y) [Tue Jul 24 03:25:33 2012] Writing source region out to fullrun_pn_xmm0007421901_pi300-10000_pass1_cl_src3_src.reg [Tue Jul 24 03:25:33 2012] Extracting stamp from image fullrun_pn_xmm0007421901_pi300-10000_cl_sm2.00.img.gz, (164, 308) - (239, 383) [Tue Jul 24 03:25:33 2012] XMMSAS bgd. selection expression = annulus(17452.310135, 30034.126251, 1087.500000, 2175.000000, X, Y) [Tue Jul 24 03:25:33 2012] Writing fullrun_pn_xmm0007421901_pi300-10000_pass1_cl_src3.gif [Tue Jul 24 03:27:19 2012] Mean detx,y = (4609.47, 8894.97) [Tue Jul 24 03:27:21 2012] Setting backscal keywords in source and bgd. spectrum [Tue Jul 24 03:27:55 2012] Binned source spectrum to 10 counts/bin [Tue Jul 24 03:27:55 2012] Setting source spectrum file to fullrun_pn_xmm0007421901_pi300-10000_pass1_cl_src3_src_b10.pi.gz [Tue Jul 24 03:27:55 2012] Setting bgd. spectrum file to fullrun_pn_xmm0007421901_pi300-10000_pass1_cl_src3_bgd.pi.gz [Tue Jul 24 03:30:54 2012] Not generating rmf since there are only 89 counts [Tue Jul 24 03:30:54 2012] rmf not generated due to insufficient counts [Tue Jul 24 03:33:32 2012] Updating aperture counts using extracted products [Tue Jul 24 03:33:32 2012] Error reading totcts from fullrun_pn_xmm0007421901_pi300-10000_pass1_cl_src3_src_b10.pi.gz [Tue Jul 24 03:33:32 2012] Calculating source flux in energy range 0.30-8.00 [Tue Jul 24 03:33:32 2012] Using photon index=1.80, rate=0.0112, arf fullrun_pn_xmm0007421901_pi300-10000_pass1_cl_src3.arf [Tue Jul 24 03:33:32 2012] Assuming count rate is from the 0.30-10.00 bandpass [Tue Jul 24 03:33:32 2012] Updating source flux to 6.4e-14 [Tue Jul 24 03:33:34 2012] Simple spatial fitting not done (or not done successfully), skipping spectral fitting [Tue Jul 24 03:33:55 2012] xmm0007421901/analysis//spectral/fullrun_pn_xmm0007421901_pi300-10000_pass1_cl_src3_pl.csv not found, spectral fit skipped or did not complete