[Fri Aug 31 18:45:23 2012] Detection parameters: Position = (203.4, 214.1) = 11 43 44.84 19 58 56.3 Extent = 10.9" x 10.9", rotation angle = 0 degrees Source counts = 87.6 +/- 18.5 Background counts = 112.3 Rate = 0.005 +/- 0.001 [Fri Aug 31 18:45:24 2012] Off-axis axis estimate = 9.21' [Fri Aug 31 18:47:28 2012] Using EEF radius (= 11.03 ")to estimate initial spatial extent for simple fitting [Fri Aug 31 18:47:28 2012] Initial guess for spatial extent in simple fitting = 11.03" [Fri Aug 31 18:47:28 2012] source mask rpix=2.5, npix_max = 36, mask sum = 36, frac = 0.976 [Fri Aug 31 18:47:28 2012] Giving source the simple spatial ID 27 for pass 0, mean size = 11.03" [Fri Aug 31 19:28:05 2012] fullrun_pn_xmm0005210101_pi300-10000_cl_pass0_src27.ximg exists [Fri Aug 31 19:28:05 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0005210101_pi300-10000_cl_pass0_src27.csv [Fri Aug 31 19:28:05 2012] fullrun_pn_xmm0005210101_pi300-10000_cl_pass0_src27_1.ximg exists [Fri Aug 31 19:28:05 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0005210101_pi300-10000_cl_pass0_src27.csv [Fri Aug 31 19:28:05 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0005210101_pi300-10000_cl_pass0_src27_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0005210101_pi300-10000_cl_pass0_src27.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Fri Aug 31 19:28:06 2012] fullrun_pn_xmm0005210101_pi300-10000_cl_pass0_tfrozen_src27.ximg exists [Fri Aug 31 19:28:06 2012] fullrun_pn_xmm0005210101_pi300-10000_cl_pass0_tfrozen_src27_1.ximg exists [Fri Aug 31 19:28:06 2012] Fit fullrun_pn_xmm0005210101_pi300-10000_cl_pass0_tfrozen_src27 appears to have run properly [Fri Aug 31 20:20:34 2012] Spatial fit model total counts = 1227.480000, observed total counts = 1197.000000 [Fri Aug 31 20:20:34 2012] Offset between fit and detection position for source 30 = 8.693643 pixels [Fri Aug 31 20:20:34 2012] 1119.382000 total counts/ 694.391000 bgd. counts: snr = 16.127895 Spatial fit parameters: Offset between fit and detection position for source 30 = 8.693643 pixels Position = (209.8, 219.9) = 11 43 42.86 19 59 19.7 Extent = 22.1 (22.0-44.1)", rotation angle = 0 Source counts = 425.0 +/- 33.5 Background counts = 694.4 Rate = 0.02 +/- 0.001 [Fri Aug 31 20:20:34 2012] Vigneting correction estimate = 1.000000 [Fri Aug 31 20:20:34 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Fri Aug 31 20:20:34 2012] Assessing source extent using major axis lower bound [Fri Aug 31 20:20:34 2012] Source does appear to be extended [Fri Aug 31 20:20:34 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Fri Aug 31 20:20:47 2012] Using previous fit value to estimate initial spatial extent for simple fitting [Fri Aug 31 20:20:47 2012] Setting initial spatial extent for simple fitting to maximum allowed for this pass [Fri Aug 31 20:20:47 2012] Initial guess for spatial extent in simple fitting = 22.07" [Fri Aug 31 20:20:47 2012] source mask rpix=5.1, npix_max = 124, mask sum = 120, frac = 0.966 [Fri Aug 31 20:20:47 2012] Giving source the simple spatial ID 26 for pass 1, mean size = 22.07" [Fri Aug 31 21:00:36 2012] fullrun_pn_xmm0005210101_pi300-10000_cl_pass1_src26.ximg exists [Fri Aug 31 21:00:36 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0005210101_pi300-10000_cl_pass1_src26.csv [Fri Aug 31 21:00:36 2012] fullrun_pn_xmm0005210101_pi300-10000_cl_pass1_src26_1.ximg exists [Fri Aug 31 21:00:36 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0005210101_pi300-10000_cl_pass1_src26.csv [Fri Aug 31 21:00:36 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0005210101_pi300-10000_cl_pass1_src26_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0005210101_pi300-10000_cl_pass1_src26.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Fri Aug 31 21:00:36 2012] fullrun_pn_xmm0005210101_pi300-10000_cl_pass1_tfrozen_src26.ximg exists [Fri Aug 31 21:00:36 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0005210101_pi300-10000_cl_pass1_tfrozen_src26.csv [Fri Aug 31 21:00:36 2012] fullrun_pn_xmm0005210101_pi300-10000_cl_pass1_tfrozen_src26_1.ximg exists [Fri Aug 31 21:00:36 2012] Warning: poor agreement between model and actual number of counts may be indicative of a poor fit in csv/fullrun_pn_xmm0005210101_pi300-10000_cl_pass1_tfrozen_src26.csv [Fri Aug 31 21:00:36 2012] It looks like the fit did not converge You should probably delete fullrun_pn_xmm0005210101_pi300-10000_cl_pass1_tfrozen_src26_1.ximg Either tweak this fit manually starting from fullrun_pn_xmm0005210101_pi300-10000_cl_pass1_tfrozen_src26.ximg or adjust the simplespatial fit parameters in $XASSIST/data/missions/*/*/spatial.dat and re-run simplespatial fitting after setting file recreation parameter to yes [Fri Aug 31 21:45:56 2012] Warning, spatial fit 26 centroid is now closest to src. 35 [Fri Aug 31 21:45:56 2012] Vigneting correction estimate = 1.000000 [Fri Aug 31 21:45:56 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Fri Aug 31 21:45:56 2012] Assessing source extent using major axis lower bound [Fri Aug 31 21:45:56 2012] Source does appear to be extended [Fri Aug 31 21:45:56 2012] Computing asymmetry using major and minor axis, asym = 1.00 [Fri Aug 31 21:46:10 2012] XMMSAS src. selection expression = ellipse(18206.602000, 19086.388000, 1324.176038, 1324.176038, 0.000000, X, Y) [Fri Aug 31 21:46:10 2012] Writing source region out to fullrun_pn_xmm0005210101_pi300-10000_pass1_cl_src30_src.reg [Fri Aug 31 21:46:10 2012] Extracting stamp from image fullrun_pn_xmm0005210101_pi300-10000_cl_sm2.00.img.gz, (134, 144) - (286, 296) [Fri Aug 31 21:46:10 2012] XMMSAS bgd. selection expression = annulus(18206.602000, 19086.388000, 2206.960064, 4413.920127, X, Y) && !ellipse(16437.958847, 17381.440765, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(14255.989395, 16552.622925, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(14930.118591, 22827.073120, 870.000000, 870.000000, 0.000000, X, Y) && !ellipse(17059.643200, 18194.426200, 643.247219, 643.247219, 0.000000, X, Y) && !ellipse(16522.139206, 17894.507919, 870.000000, 870.000000, 0.000000, X, Y) [Fri Aug 31 21:46:10 2012] Writing fullrun_pn_xmm0005210101_pi300-10000_pass1_cl_src30.gif [Fri Aug 31 21:57:42 2012] Mean detx,y = (9231.18, -142.20) [Fri Aug 31 21:57:44 2012] Setting backscal keywords in source and bgd. spectrum [Fri Aug 31 21:58:27 2012] grppha failed [Fri Aug 31 21:58:28 2012] Setting source spectrum file to fullrun_pn_xmm0005210101_pi300-10000_pass1_cl_src30_src.pi.gz [Fri Aug 31 21:58:28 2012] Setting bgd. spectrum file to fullrun_pn_xmm0005210101_pi300-10000_pass1_cl_src30_bgd.pi.gz [Fri Aug 31 22:10:14 2012] Updating aperture counts using extracted products [Fri Aug 31 22:10:14 2012] Error reading totcts from fullrun_pn_xmm0005210101_pi300-10000_pass1_cl_src30_src.pi.gz [Fri Aug 31 22:10:14 2012] No arf file for this source, not re-computing flux [Fri Aug 31 22:10:18 2012] Source 30 has no response, skipping [Fri Aug 31 22:10:19 2012] xmm0005210101/analysis//spectral/fullrun_pn_xmm0005210101_pi300-10000_pass1_cl_src30_pl.csv not found, spectral fit skipped or did not complete