fullrun_all_xmm0005010101

Processing completion:

Field: xmm0005010101

Detector Exposure (Original/High-E Flare Cleaned/Low-E Cleaned) Image binning Plate scale ("/pixel) Bgd. level (orig/High-E flare cleaned/cleaned, counts/sq. arcmin/s) GTI file Bgd. light curves Roll angle CCD counts Extra info
mos1 27395 | 27395 | 25727 1.00 4.35 0/0 Yes orig clean ccd1:39134 ccd2:8603 ccd3:10843 ccd4:8409 ccd5:9197 ccd6:10225 ccd7:8117 filter=Medium
date-obs=2003-01-01T22:58:34
object=Mkn478
roll_angle=111.71697998
mos2 27405 | 27391 | 25916 1.00 4.35 0/0 Yes orig clean ccd1:38879 ccd2:7684 ccd3:8443 ccd4:7209 ccd5:7588 ccd6:10230 ccd7:8220 filter=Medium
date-obs=2003-01-01T22:58:35
object=Mkn478
roll_angle=111.71697998
pn 24582 | 24582 | 24578 1.00 4.35 0/0 Yes orig clean ccd4:125447 filter=Medium
date-obs=2003-01-01T23:48:30
object=Mkn478
timedel=0.00
roll_angle=111.71697998

Source List (gives positions and fluxes and links for detailed analyses)

12 source(s) in memory
Iteration: 2
Images:
|mos1 |mos2 |pn |
PackageState
init Complete
acquire Complete
reduce Complete
detect Complete
timeclean Complete
simplespatial Complete
assess Complete
extract Complete
reassess Complete
spectral Complete
temporal Complete
spatial Complete
correl Skip
sim Skip
qlook Skip
xray image
skyview image

Xray image, smoothed with a 2 pixel gaussian

Skyview image(s) of FOV (with X-ray sources marked)

Color code (marks may only appear on detector-specific images for multi-detector missions, see links above): green = point source, red = problematic/questionable source, blue = extended source, magenta = asymmetric source (may be extended), cyan = estimated detector boundary, purple = "Region of Interest" (if set)

Python version = 2.5.4 (r254:67916, Aug 14 2009, 18:07:15) [GCC 4.1.1 20070105 (Red Hat 4.1.1-52)]
Headas version = 6.11
XAssist version = 1.000
SAS version = xmmsas_20110223_1801-11.0.0
numpy version = 1.3.0
Pyfits version = 2.1.1
XAssist originally started on this data set at Fri Jul 13 03:11:08 2012
This data set was last accessed on Fri Jul 13 03:11:08 2012
Current user = xassist on x3.localdomain
Number of fields in memory = 1
Current field being processed = xmm0005010101
Position of field target = 14 42 7.40 35 26 23.0
Current telescope = xmm
Current detector = all
Processing mode = proc
Processing status = OK
Detection method = eboxdetect
Batch processing enabled
Place data, logs, etc. in field subdirectories
Image analysis will be over range of allowed energies
Will analyze each ccd separately

Log files: processing messages |error messages |all messages (very detailed) |source logs