[Wed Oct 26 15:49:12 2011] Detection parameters: Position = (452.5, 1101.5) = 14 18 33.48 52 33 52.7 Extent = 0.5" x 0.5", rotation angle = 90 degrees Source counts = 6.3 +/- 2.6 Background counts = 0.7 Rate = 0.0001 +/- 4e-05 [Wed Oct 26 15:49:13 2011] Off-axis axis estimate = 4.48' [Wed Oct 26 15:50:29 2011] Using EEF radius (= 0.99 ")to estimate initial spatial extent for simple fitting [Wed Oct 26 15:50:29 2011] Initial guess for spatial extent in simple fitting = 0.99" [Wed Oct 26 15:50:29 2011] Spatial fitting skipped for pass 0: source has 6.3 net counts, is at off-axis angle 4.5' [Wed Oct 26 15:50:43 2011] Vigneting correction estimate = 1.000000 [Wed Oct 26 15:50:43 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Wed Oct 26 15:50:43 2011] Assessing source extent using major [Wed Oct 26 15:50:43 2011] Source does appear to be extended [Wed Oct 26 15:50:43 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Wed Oct 26 15:51:16 2011] Using EEF radius (= 0.99 ")to estimate initial spatial extent for simple fitting [Wed Oct 26 15:51:16 2011] Initial guess for spatial extent in simple fitting = 0.99" [Wed Oct 26 15:51:16 2011] Spatial fitting skipped for pass 1: source has 6.3 net counts, is at off-axis angle 4.5' [Wed Oct 26 15:51:29 2011] Vigneting correction estimate = 1.000000 [Wed Oct 26 15:51:29 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Wed Oct 26 15:51:29 2011] Assessing source extent using major [Wed Oct 26 15:51:29 2011] Source does appear to be extended [Wed Oct 26 15:51:29 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Wed Oct 26 15:51:29 2011] Deleting source due to low Poisson probability 0.9