skip = machinename xassist.localdomain process id = 15221: smart_fit pl logroot=fullrun_ccd3_acisf09738_pi14-548_pass1_cl_src11_pl flux_elow=0.300000 flux_ehi=8.000000 2 parameters in pl dchi = 4.605 F(2.0-10.0 keV) = 1.448e-14 Count rates: 0.002887 Entry point parameter values: Nh = 5.72e-10 () Gamma = 2.16 () Starting error search... Getting error on parameter #2 = Nh smart_error exited normally Hard limit reached before req. deltachisq for lower bound Nh = 5.72e-10 (0 - 0.222) Getting error on parameter #3 = Gamma smart_error exited normally Gamma = 2.16 (1.74 - 2.62) Saving fit as fullrun_ccd3_acisf09738_pi14-548_pass1_cl_src11_pl_new.xcm in order to save the revised "delta" values (to improve future error search efficiency) Final chisq(dof) = 14.222(13) F(0.5-2.0 keV) = 1.58e-14 F(2.0-10.0 keV) = 1.448e-14 F(0.3-8.0) = 3.526e-14 Count rates: 0.002887