[Tue Oct 4 08:53:40 2011] Detection parameters: Position = (942.8, 670.8) = 17 42 0.84 -28 44 10.6 Extent = 0.5" x 0.5", rotation angle = 33 degrees Source counts = 5.7 +/- 2.4 Background counts = 0.3 Rate = 0.0004 +/- 0.0002 [Tue Oct 4 08:53:41 2011] Off-axis axis estimate = 3.82' [Tue Oct 4 08:54:20 2011] Using EEF radius (= 0.78 ")to estimate initial spatial extent for simple fitting [Tue Oct 4 08:54:20 2011] Initial guess for spatial extent in simple fitting = 0.78" [Tue Oct 4 08:54:20 2011] Spatial fitting skipped for pass 0: source has 5.7 net counts, is at off-axis angle 3.8' [Tue Oct 4 08:54:27 2011] Vigneting correction estimate = 1.000000 [Tue Oct 4 08:54:27 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Oct 4 08:54:27 2011] Assessing source extent using major [Tue Oct 4 08:54:27 2011] Source does appear to be extended [Tue Oct 4 08:54:27 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Tue Oct 4 08:54:27 2011] Deleting source due to low Poisson probability 0.8