[Thu Oct 6 02:47:42 2011] Detection parameters: Position = (798.9, 794.8) = 3 44 31.29 32 3 51.7 Extent = 0.7" x 0.5", rotation angle = 10 degrees Source counts = 8.7 +/- 3.2 Background counts = 1.3 Rate = 0.0002 +/- 6e-05 [Thu Oct 6 02:47:47 2011] Off-axis axis estimate = 3.96' [Thu Oct 6 02:49:31 2011] Using EEF radius (= 0.82 ")to estimate initial spatial extent for simple fitting [Thu Oct 6 02:49:31 2011] Initial guess for spatial extent in simple fitting = 0.82" [Thu Oct 6 02:49:31 2011] Spatial fitting skipped for pass 0: source has 8.7 net counts, is at off-axis angle 4.0' [Thu Oct 6 02:50:00 2011] Vigneting correction estimate = 1.000000 [Thu Oct 6 02:50:00 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Thu Oct 6 02:50:00 2011] Assessing source extent using major [Thu Oct 6 02:50:00 2011] Source does appear to be extended [Thu Oct 6 02:50:00 2011] Computing asymmetry using major and minor axis, asym = 1.45 [Thu Oct 6 02:50:00 2011] Deleting source due to low Poisson probability 0.8