[Thu Oct 6 23:01:04 2011] Detection parameters: Position = (682.6, 845.3) = 18 6 35.65 69 50 16.3 Extent = 0.5" x 0.5", rotation angle = 155 degrees Source counts = 9.7 +/- 3.2 Background counts = 0.3 Rate = 0.001 +/- 0.0003 [Thu Oct 6 23:01:04 2011] Off-axis axis estimate = 1.41' [Thu Oct 6 23:01:35 2011] Using EEF radius (= 0.39 ")to estimate initial spatial extent for simple fitting [Thu Oct 6 23:01:35 2011] Initial guess for spatial extent in simple fitting = 0.39" [Thu Oct 6 23:01:35 2011] Spatial fitting skipped for pass 0: source has 9.7 net counts, is at off-axis angle 1.4' [Thu Oct 6 23:01:39 2011] Vigneting correction estimate = 1.000000 [Thu Oct 6 23:01:39 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Thu Oct 6 23:01:39 2011] Assessing source extent using major [Thu Oct 6 23:01:39 2011] Source does appear to be extended [Thu Oct 6 23:01:39 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Thu Oct 6 23:01:50 2011] Using EEF radius (= 0.39 ")to estimate initial spatial extent for simple fitting [Thu Oct 6 23:01:50 2011] Initial guess for spatial extent in simple fitting = 0.39" [Thu Oct 6 23:01:50 2011] Spatial fitting skipped for pass 1: source has 9.7 net counts, is at off-axis angle 1.4' [Thu Oct 6 23:01:54 2011] Vigneting correction estimate = 1.000000 [Thu Oct 6 23:01:54 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Thu Oct 6 23:01:54 2011] Assessing source extent using major [Thu Oct 6 23:01:54 2011] Source does appear to be extended [Thu Oct 6 23:01:54 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Thu Oct 6 23:01:54 2011] Deleting source due to low Poisson probability 0.9