[Thu Sep 22 15:59:10 2011] Detection parameters: Position = (1034.6, 710.5) = 10 0 23.27 2 1 17.1 Extent = 0.5" x 0.5", rotation angle = 27 degrees Source counts = 6.3 +/- 2.6 Background counts = 0.7 Rate = 0.0001 +/- 6e-05 [Thu Sep 22 15:59:11 2011] Off-axis axis estimate = 3.96' [Thu Sep 22 16:00:27 2011] Using EEF radius (= 0.82 ")to estimate initial spatial extent for simple fitting [Thu Sep 22 16:00:27 2011] Initial guess for spatial extent in simple fitting = 0.82" [Thu Sep 22 16:00:27 2011] Spatial fitting skipped for pass 0: source has 6.3 net counts, is at off-axis angle 4.0' [Thu Sep 22 16:00:45 2011] Vigneting correction estimate = 1.000000 [Thu Sep 22 16:00:45 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Thu Sep 22 16:00:45 2011] Assessing source extent using major [Thu Sep 22 16:00:45 2011] Source does appear to be extended [Thu Sep 22 16:00:45 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Thu Sep 22 16:01:17 2011] Using EEF radius (= 0.82 ")to estimate initial spatial extent for simple fitting [Thu Sep 22 16:01:17 2011] Initial guess for spatial extent in simple fitting = 0.82" [Thu Sep 22 16:01:17 2011] Spatial fitting skipped for pass 1: source has 6.3 net counts, is at off-axis angle 4.0' [Thu Sep 22 16:01:33 2011] Vigneting correction estimate = 1.000000 [Thu Sep 22 16:01:33 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Thu Sep 22 16:01:33 2011] Assessing source extent using major [Thu Sep 22 16:01:33 2011] Source does appear to be extended [Thu Sep 22 16:01:33 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Thu Sep 22 16:01:33 2011] Deleting source due to low Poisson probability 0.9