skip = machinename xassist.localdomain process id = 20431: smart_fit pl logroot=fullrun_ccd2_acisf08001_pi14-548_pass1_cl_src1_pl flux_elow=0.300000 flux_ehi=8.000000 2 parameters in pl dchi = 4.605 F(2.0-10.0 keV) = 3.592e-14 Count rates: 0.003759 Entry point parameter values: Nh = 0.22 () Gamma = 1.82 () Starting error search... Getting error on parameter #2 = Nh smart_error exited normally Hard limit reached before req. deltachisq for lower bound Nh = 0.22 (0 - 0.602) Getting error on parameter #3 = Gamma smart_error exited normally Gamma = 1.82 (1.3 - 2.45) Saving fit as fullrun_ccd2_acisf08001_pi14-548_pass1_cl_src1_pl_new.xcm in order to save the revised "delta" values (to improve future error search efficiency) Final chisq(dof) = 14.173(15) F(0.5-2.0 keV) = 1.401e-14 F(2.0-10.0 keV) = 3.592e-14 F(0.3-8.0) = 4.468e-14 Count rates: 0.003759