[Thu Sep 22 15:31:39 2011] Detection parameters: Position = (621.2, 257.9) = 13 25 26.49 -42 56 41.9 Extent = 0.5" x 0.5", rotation angle = 111 degrees Source counts = 6.9 +/- 3.0 Background counts = 2.1 Rate = 8e-05 +/- 3e-05 [Thu Sep 22 15:31:43 2011] Off-axis axis estimate = 4.29' [Thu Sep 22 15:34:30 2011] Using EEF radius (= 0.92 ")to estimate initial spatial extent for simple fitting [Thu Sep 22 15:34:30 2011] Initial guess for spatial extent in simple fitting = 0.92" [Thu Sep 22 15:34:30 2011] Spatial fitting skipped for pass 0: source has 6.9 net counts, is at off-axis angle 4.3' [Thu Sep 22 15:35:25 2011] Vigneting correction estimate = 1.000000 [Thu Sep 22 15:35:25 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Thu Sep 22 15:35:25 2011] Assessing source extent using major [Thu Sep 22 15:35:25 2011] Source does appear to be extended [Thu Sep 22 15:35:25 2011] Computing asymmetry using major and minor axis, asym = 1.11 [Thu Sep 22 15:35:25 2011] Deleting source due to low Poisson probability 0.9