Source List

Observation details report
Detailed source parameters (including errors) in a comma-separated values file

Click on source number for detailed analysis, including spectral fits if applicable

data idnum idradec telescope instrument x y cnts cntserr rate rateerr SNR poisprob sigmaj sigmin incang offax cnts_soft cnts_hard hr hr_err ext var N_H flux vign flags
Report srcpi bgdpi arf 1 X170324.50+602947.8 chandra ccd7 184.034 336.77 20.3284 4.5087 0.00432238 0.000958676 16.2212 1 1.5 0.686897 76.981 5.19231 A F 1.93e+20 4.6853e-14 1 dsx
Report srcpi bgdpi arf 2 X170258.07+602917.7 chandra ccd7 580.25 274.5 3.65947 2.00001 0.000778104 0.000425257 2.9201 0.994464 0.492 0.492 90 2.04272 F F 1.9e+20 6.08029e-15 1 dx
Report srcpi bgdpi arf 3 X170327.85+603033.5 chandra ccd7 133.5 429.333 10.0804 3.46413 0.00214337 0.00073657 8.04373 1 1.32361 1.05056 122.764 5.85977 F F 1.93e+20 1.67137e-14 1 dx
Report srcpi bgdpi arf 4 X170236.66+602815.4 chandra ccd7 902.391 148.233 13.0192 3.60821 0.00276825 0.000767209 10.3887 1 0.371261 0.371261 0 1.00573 F F 1.88e+20 3.17037e-14 1 dsx

counts and rate are bgd.-subtracted, based on simple spatial fitting (if done) or extracted counts from aperture otherwise (N.B., in either case aperture counts are given csv file).
cntserr, rateerr = Error on (source) counts and count rate, based on error in total counts
SNR = signal-to-noise ratio, computed using Nsrc/sqrt(Nbgd)
poisprob = Poisson probability of observing total counts given bgd. counts
sigmaj, sigmin = source extent (from detection output or spatial fitting) in units of arcsecs.
incang = position angle of source (inclination from x-axis)
cnts_soft = bgd.-subtracted counts in soft band (0.50 - 2.00 KeV, always taken directly from source aperture rather than model fitting)
cnts_hard = bgd.-subtracted counts in hard band (2.00 - 7.99 KeV, always taken directly from source aperture rather than model fitting)
hr, hr_err = hardness ratio ([cnts_hard-cnts_soft]/[cnts_hard+cnts_soft]) and error
ext = source extension flag: F = false (not extended), T = true (extended), A = asymetric (ratio of sigmaj/sigmin > 1 + x, where x = 0.5 by default)
var = variability flag: U = unknown, F = false (is not variable), T = true
N_H = Galactic column density as determined from LHEASOFT nh program
flux = flux determined from count rate using pimms (in the 0.30-8.00 keV bandpass for a power-law model with ph. index = 1.8)
vign = vignetting correction
Flags: d = detection parameters, s = simple spatial fitting parameters, b = simple spatial fitting failed, p = poor simple spatial fit, x = extracted events parameters, t = temporal anaylsis parameters, i = psf spatial fitting parameters, f = spectral fitting parameters, c = source is confused, u = user-defined source, v = detected source coincident with user-defined source, r = source is in region-of-interest