[Tue Mar 13 10:51:35 2012] Detection parameters: Position = (344.5, 947.0) = 2 41 12.66 -8 12 30.1 Extent = 0.6" x 0.5", rotation angle = 8 degrees Source counts = 6.4 +/- 2.8 Background counts = 1.6 Rate = 0.0001 +/- 5e-05 [Tue Mar 13 10:51:35 2012] Off-axis axis estimate = 1.73' [Tue Mar 13 10:52:31 2012] Using EEF radius (= 0.41 ")to estimate initial spatial extent for simple fitting [Tue Mar 13 10:52:31 2012] Initial guess for spatial extent in simple fitting = 0.41" [Tue Mar 13 10:52:31 2012] Spatial fitting skipped for pass 0: source has 6.4 net counts, is at off-axis angle 1.7' [Tue Mar 13 10:52:51 2012] Vigneting correction estimate = 1.000000 [Tue Mar 13 10:52:51 2012] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Mar 13 10:52:51 2012] Assessing source extent using major [Tue Mar 13 10:52:51 2012] Source does appear to be extended [Tue Mar 13 10:52:51 2012] Computing asymmetry using major and minor axis, asym = 1.25 [Tue Mar 13 10:52:51 2012] Deleting source due to low Poisson probability 0.9