[Mon Oct 24 21:39:57 2011] Detection parameters: Position = (578.5, 995.4) = 17 44 2.10 -29 27 55.2 Extent = 0.6" x 0.5", rotation angle = 72 degrees Source counts = 6.3 +/- 2.8 Background counts = 1.7 Rate = 6e-05 +/- 3e-05 [Mon Oct 24 21:39:57 2011] Off-axis axis estimate = 4.49' [Mon Oct 24 21:42:22 2011] Using EEF radius (= 0.99 ")to estimate initial spatial extent for simple fitting [Mon Oct 24 21:42:22 2011] Initial guess for spatial extent in simple fitting = 0.99" [Mon Oct 24 21:42:22 2011] Spatial fitting skipped for pass 0: source has 6.3 net counts, is at off-axis angle 4.5' [Mon Oct 24 21:42:54 2011] Vigneting correction estimate = 1.000000 [Mon Oct 24 21:42:54 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Mon Oct 24 21:42:54 2011] Assessing source extent using major [Mon Oct 24 21:42:54 2011] Source does appear to be extended [Mon Oct 24 21:42:54 2011] Computing asymmetry using major and minor axis, asym = 1.19 [Mon Oct 24 21:42:54 2011] Deleting source due to low Poisson probability 0.8