[Thu Sep 29 17:27:19 2011] Detection parameters: Position = (481.5, 443.5) = 4 20 47.12 -50 22 25.7 Extent = 0.5" x 0.5", rotation angle = 90 degrees Source counts = 0.8 +/- 1.0 Background counts = 0.2 Rate = 4e-05 +/- 5e-05 [Thu Sep 29 17:27:19 2011] Off-axis axis estimate = 7.12' [Thu Sep 29 17:28:01 2011] Using EEF radius (= 2.25 ")to estimate initial spatial extent for simple fitting [Thu Sep 29 17:28:01 2011] Initial guess for spatial extent in simple fitting = 2.25" [Thu Sep 29 17:28:01 2011] Spatial fitting skipped for pass 0: source has 0.8 net counts, is at off-axis angle 7.1' [Thu Sep 29 17:28:07 2011] Vigneting correction estimate = 1.000000 [Thu Sep 29 17:28:07 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Thu Sep 29 17:28:07 2011] Assessing source extent using major [Thu Sep 29 17:28:07 2011] Source does appear to be extended [Thu Sep 29 17:28:07 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Thu Sep 29 17:28:07 2011] Deleting source due to low Poisson probability 0.7