[Thu Sep 29 16:13:32 2011] Detection parameters: Position = (790.9, 1075.1) = 14 30 25.68 -62 39 11.4 Extent = 1.0" x 0.5", rotation angle = 29 degrees Source counts = 7.3 +/- 2.8 Background counts = 0.7 Rate = 0.0002 +/- 0.0001 [Thu Sep 29 16:13:32 2011] Off-axis axis estimate = 4.71' [Thu Sep 29 16:14:31 2011] Using EEF radius (= 1.07 ")to estimate initial spatial extent for simple fitting [Thu Sep 29 16:14:31 2011] Initial guess for spatial extent in simple fitting = 1.07" [Thu Sep 29 16:14:31 2011] Spatial fitting skipped for pass 0: source has 7.3 net counts, is at off-axis angle 4.7' [Thu Sep 29 16:14:43 2011] Vigneting correction estimate = 1.000000 [Thu Sep 29 16:14:43 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Thu Sep 29 16:14:43 2011] Assessing source extent using major [Thu Sep 29 16:14:43 2011] Source does appear to be extended [Thu Sep 29 16:14:43 2011] Computing asymmetry using major and minor axis, asym = 2.07 [Thu Sep 29 16:14:43 2011] Source is asymmetric [Thu Sep 29 16:14:43 2011] Deleting source due to low Poisson probability 1.0