[Fri Oct 14 14:57:33 2011] Detection parameters: Position = (855.5, 182.1) = 12 15 13.42 47 7 8.0 Extent = 0.6" x 0.5", rotation angle = 13 degrees Source counts = 6.2 +/- 2.6 Background counts = 0.8 Rate = 9e-05 +/- 4e-05 [Fri Oct 14 14:57:33 2011] Off-axis axis estimate = 5.07' [Fri Oct 14 14:58:38 2011] Using EEF radius (= 1.21 ")to estimate initial spatial extent for simple fitting [Fri Oct 14 14:58:38 2011] Initial guess for spatial extent in simple fitting = 1.21" [Fri Oct 14 14:58:38 2011] Spatial fitting skipped for pass 0: source has 6.2 net counts, is at off-axis angle 5.1' [Fri Oct 14 14:58:49 2011] Vigneting correction estimate = 1.000000 [Fri Oct 14 14:58:49 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Fri Oct 14 14:58:49 2011] Assessing source extent using major [Fri Oct 14 14:58:49 2011] Source does appear to be extended [Fri Oct 14 14:58:49 2011] Computing asymmetry using major and minor axis, asym = 1.16 [Fri Oct 14 14:59:14 2011] Using EEF radius (= 1.21 ")to estimate initial spatial extent for simple fitting [Fri Oct 14 14:59:14 2011] Initial guess for spatial extent in simple fitting = 1.21" [Fri Oct 14 14:59:14 2011] Spatial fitting skipped for pass 1: source has 6.2 net counts, is at off-axis angle 5.1' [Fri Oct 14 14:59:25 2011] Vigneting correction estimate = 1.000000 [Fri Oct 14 14:59:25 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Fri Oct 14 14:59:25 2011] Assessing source extent using major [Fri Oct 14 14:59:25 2011] Source does appear to be extended [Fri Oct 14 14:59:25 2011] Computing asymmetry using major and minor axis, asym = 1.16 [Fri Oct 14 14:59:25 2011] Deleting source due to low Poisson probability 0.9