[Sat Oct 1 10:41:59 2011] Detection parameters: Position = (226.8, 218.2) = 6 33 22.86 22 35 5.3 Extent = 0.5" x 0.5", rotation angle = 108 degrees Source counts = 6.1 +/- 2.6 Background counts = 0.9 Rate = 0.0002 +/- 7e-05 [Sat Oct 1 10:41:59 2011] Off-axis axis estimate = 0.55' [Sat Oct 1 10:42:34 2011] Using EEF radius (= 0.39 ")to estimate initial spatial extent for simple fitting [Sat Oct 1 10:42:34 2011] Initial guess for spatial extent in simple fitting = 0.39" [Sat Oct 1 10:42:34 2011] Spatial fitting skipped for pass 0: source has 6.1 net counts, is at off-axis angle 0.6' [Sat Oct 1 10:42:43 2011] Vigneting correction estimate = 1.000000 [Sat Oct 1 10:42:43 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Sat Oct 1 10:42:43 2011] Assessing source extent using major [Sat Oct 1 10:42:43 2011] Source does appear to be extended [Sat Oct 1 10:42:43 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Sat Oct 1 10:42:59 2011] Using EEF radius (= 0.39 ")to estimate initial spatial extent for simple fitting [Sat Oct 1 10:42:59 2011] Initial guess for spatial extent in simple fitting = 0.39" [Sat Oct 1 10:42:59 2011] Spatial fitting skipped for pass 1: source has 6.1 net counts, is at off-axis angle 0.6' [Sat Oct 1 10:43:06 2011] Vigneting correction estimate = 1.000000 [Sat Oct 1 10:43:06 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Sat Oct 1 10:43:06 2011] Assessing source extent using major [Sat Oct 1 10:43:06 2011] Source does appear to be extended [Sat Oct 1 10:43:06 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Sat Oct 1 10:44:37 2011] Not overwriting source region fullrun_ccd7_acisf04467_pi14-548_pass1_cl_src6_src.reg [Sat Oct 1 10:44:37 2011] Extracting stamp from image fullrun_ccd7_acisf04467_pi14-548_cl_sm2.00.img.gz, (204, 196) - (249, 241) [Sat Oct 1 10:44:37 2011] Writing fullrun_ccd7_acisf04467_pi14-548_pass1_cl_src6.gif [Sat Oct 1 10:45:30 2011] ../../acisf04467/products/events/fullrun_ccd7_acisf04467_pi14-548_pass1_cl_src6_src.evt and ../../acisf04467/products/events/fullrun_ccd7_acisf04467_pi14-548_pass1_cl_src6_bgd.evt exist, delete to re-create [Sat Oct 1 10:45:30 2011] Size of ../../acisf04467/products/events/fullrun_ccd7_acisf04467_pi14-548_pass1_cl_src6_src.evt.gz[events] = 7 counts [Sat Oct 1 10:45:30 2011] Mean chipx,y = (200.71, 445.00) [Sat Oct 1 10:45:30 2011] Mean tdetx,y = (4117.71, 2147.00) [Sat Oct 1 10:45:30 2011] chipx,y range = (185.00-215.00, 431.00-458.00) [Sat Oct 1 10:45:30 2011] Size of ../../acisf04467/products/events/fullrun_ccd7_acisf04467_pi14-548_pass1_cl_src6_bgd.evt.gz[events] = 13 counts [Sat Oct 1 10:45:30 2011] ../../acisf04467/products/images/fullrun_ccd7_acisf04467_pi14-548_pass1_cl_src6_src.img and ../../acisf04467/products/images/fullrun_ccd7_acisf04467_pi14-548_pass1_cl_src6_bgd.img exist, delete to re-create [Sat Oct 1 10:45:30 2011] ../../acisf04467/products/spectra/fullrun_ccd7_acisf04467_pi14-548_pass1_cl_src6_src.pi and ../../acisf04467/products/spectra/fullrun_ccd7_acisf04467_pi14-548_pass1_cl_src6_bgd.pi exist, delete to re-create [Sat Oct 1 10:45:30 2011] Not generating rmf since there are only 6 counts [Sat Oct 1 10:45:33 2011] ../../acisf04467/products/lightcurves/fullrun_ccd7_acisf04467_pi14-548_pass1_cl_src6_src.lc and ../../acisf04467/products/lightcurves/fullrun_ccd7_acisf04467_pi14-548_pass1_cl_src6_bgd.lc exist, delete to re-create [Sat Oct 1 10:45:35 2011] 239.468 [Sat Oct 1 10:45:37 2011] Updating aperture counts using extracted products [Sat Oct 1 10:45:37 2011] Error reading totcts from fullrun_ccd7_acisf04467_pi14-548_pass1_cl_src6_src.pi.gz [Sat Oct 1 10:45:37 2011] Calculating source flux in energy range 0.30-8.00 [Sat Oct 1 10:45:37 2011] Using photon index=1.80, rate=0.000168, arf fullrun_ccd7_acisf04467_pi14-548_pass1_cl_src6.arf [Sat Oct 1 10:45:37 2011] Assuming count rate is from the 0.20-8.00 bandpass [Sat Oct 1 10:45:37 2011] Updating source flux to 1.4e-15 [Sat Oct 1 10:46:12 2011] Simple spatial fitting not done (or not done successfully), skipping spectral fitting