[Fri Oct 7 13:31:48 2011] Detection parameters: Position = (495.0, 630.2) = 14 27 29.87 32 38 4.9 Extent = 0.6" x 0.5", rotation angle = 56 degrees Source counts = 3.9 +/- 2.0 Background counts = 0.1 Rate = 0.0008 +/- 0.0004 [Fri Oct 7 13:31:49 2011] Off-axis axis estimate = 4.10' [Fri Oct 7 13:32:26 2011] Using EEF radius (= 0.86 ")to estimate initial spatial extent for simple fitting [Fri Oct 7 13:32:26 2011] Initial guess for spatial extent in simple fitting = 0.86" [Fri Oct 7 13:32:26 2011] Spatial fitting skipped for pass 0: source has 3.9 net counts, is at off-axis angle 4.1' [Fri Oct 7 13:32:35 2011] Vigneting correction estimate = 1.000000 [Fri Oct 7 13:32:35 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Fri Oct 7 13:32:35 2011] Assessing source extent using major [Fri Oct 7 13:32:35 2011] Source does appear to be extended [Fri Oct 7 13:32:35 2011] Computing asymmetry using major and minor axis, asym = 1.29 [Fri Oct 7 13:32:35 2011] Deleting source due to low Poisson probability 0.9