[Tue Oct 25 22:22:56 2011] Detection parameters: Position = (263.1, 731.2) = 20 4 32.79 33 34 3.2 Extent = 0.5" x 0.5", rotation angle = 151 degrees Source counts = 8.4 +/- 3.0 Background counts = 0.6 Rate = 0.0002 +/- 8e-05 [Tue Oct 25 22:22:57 2011] Off-axis axis estimate = 4.90' [Tue Oct 25 22:23:51 2011] Using EEF radius (= 1.14 ")to estimate initial spatial extent for simple fitting [Tue Oct 25 22:23:51 2011] Initial guess for spatial extent in simple fitting = 1.14" [Tue Oct 25 22:23:51 2011] Spatial fitting skipped for pass 0: source has 8.4 net counts, is at off-axis angle 4.9' [Tue Oct 25 22:23:58 2011] Vigneting correction estimate = 1.000000 [Tue Oct 25 22:23:58 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Oct 25 22:23:58 2011] Assessing source extent using major [Tue Oct 25 22:23:58 2011] Source does appear to be extended [Tue Oct 25 22:23:58 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Tue Oct 25 22:24:18 2011] Using EEF radius (= 1.14 ")to estimate initial spatial extent for simple fitting [Tue Oct 25 22:24:18 2011] Initial guess for spatial extent in simple fitting = 1.14" [Tue Oct 25 22:24:18 2011] Spatial fitting skipped for pass 1: source has 8.4 net counts, is at off-axis angle 4.9' [Tue Oct 25 22:24:28 2011] Vigneting correction estimate = 1.000000 [Tue Oct 25 22:24:28 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue Oct 25 22:24:28 2011] Assessing source extent using major [Tue Oct 25 22:24:28 2011] Source does appear to be extended [Tue Oct 25 22:24:28 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Tue Oct 25 22:24:28 2011] Deleting source due to low Poisson probability 0.9