[Wed Oct 19 22:31:36 2011] Detection parameters: Position = (343.5, 971.5) = 7 57 3.23 45 3 54.4 Extent = 0.5" x 0.5", rotation angle = 90 degrees Source counts = 0.9 +/- 1.0 Background counts = 0.1 Rate = 0.0001 +/- 0.0001 [Wed Oct 19 22:31:36 2011] Off-axis axis estimate = 1.75' [Wed Oct 19 22:32:04 2011] Using EEF radius (= 0.41 ")to estimate initial spatial extent for simple fitting [Wed Oct 19 22:32:04 2011] Initial guess for spatial extent in simple fitting = 0.41" [Wed Oct 19 22:32:04 2011] Spatial fitting skipped for pass 0: source has 0.9 net counts, is at off-axis angle 1.7' [Wed Oct 19 22:32:09 2011] Vigneting correction estimate = 1.000000 [Wed Oct 19 22:32:09 2011] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Wed Oct 19 22:32:09 2011] Assessing source extent using major [Wed Oct 19 22:32:09 2011] Source does appear to be extended [Wed Oct 19 22:32:09 2011] Computing asymmetry using major and minor axis, asym = 1.00 [Wed Oct 19 22:32:09 2011] Deleting source due to low Poisson probability 0.8