[Fri May 17 17:37:51 2013] Detection parameters: Position = (177.5, 180.5) = 3 17 3.73 42 13 33.4 Extent = 1.3" x 0.7", rotation angle = 121 degrees Source counts = 6.3 +/- 2.8 Background counts = 1.7 Rate = 0.0002 +/- 8e-05 [Fri May 17 17:37:51 2013] Off-axis axis estimate = 6.58' [Fri May 17 18:10:21 2013] Using EEF radius (= 1.94 ")to estimate initial spatial extent for simple fitting [Fri May 17 18:10:21 2013] Initial guess for spatial extent in simple fitting = 1.94" [Fri May 17 18:10:21 2013] Spatial fitting skipped for pass 0: source has 6.3 net counts, is at off-axis angle 6.6' [Fri May 17 18:48:30 2013] Vigneting correction estimate = 1.000000 [Fri May 17 18:48:30 2013] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Fri May 17 18:48:30 2013] Assessing source extent using major [Fri May 17 18:48:30 2013] Source does appear to be extended [Fri May 17 18:48:30 2013] Computing asymmetry using major and minor axis, asym = 1.89 [Fri May 17 18:48:30 2013] Source is asymmetric [Fri May 17 19:18:21 2013] Using EEF radius (= 1.94 ")to estimate initial spatial extent for simple fitting [Fri May 17 19:18:21 2013] Initial guess for spatial extent in simple fitting = 1.94" [Fri May 17 19:18:21 2013] Spatial fitting skipped for pass 1: source has 6.3 net counts, is at off-axis angle 6.6' [Fri May 17 19:57:15 2013] Vigneting correction estimate = 1.000000 [Fri May 17 19:57:15 2013] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Fri May 17 19:57:15 2013] Assessing source extent using major [Fri May 17 19:57:15 2013] Source does appear to be extended [Fri May 17 19:57:15 2013] Computing asymmetry using major and minor axis, asym = 1.89 [Fri May 17 19:57:15 2013] Source is asymmetric [Fri May 17 20:18:55 2013] Writing source region out to fullrun_ccd2_acisf13990_pi14-548_pass1_cl_src19_src.reg [Fri May 17 20:18:55 2013] Extracting stamp from image fullrun_ccd2_acisf13990_pi14-548_cl_sm2.00.img.gz, (118, 121) - (237, 240) [Fri May 17 20:18:55 2013] Writing fullrun_ccd2_acisf13990_pi14-548_pass1_cl_src19.gif [Fri May 17 20:30:37 2013] Size of ../../acisf13990/products/events/fullrun_ccd2_acisf13990_pi14-548_pass1_cl_src19_src.evt.gz[events] = 8 counts [Fri May 17 20:30:37 2013] Mean chipx,y = (853.62, 915.75) [Fri May 17 20:30:37 2013] Mean tdetx,y = (3976.75, 3232.38) [Fri May 17 20:30:37 2013] chipx,y range = (842.00-878.00, 898.00-933.00) [Fri May 17 20:30:37 2013] Size of ../../acisf13990/products/events/fullrun_ccd2_acisf13990_pi14-548_pass1_cl_src19_bgd.evt.gz[events] = 29 counts [Fri May 17 20:30:38 2013] Not generating rmf since there are only 6 counts [Fri May 17 20:30:38 2013] arf not found, will run specextract [Fri May 17 20:31:07 2013] ../../acisf13990/products/spectra/fullrun_ccd2_acisf13990_pi14-548_pass1_cl_src19.warf not found [Fri May 17 20:31:07 2013] ../../acisf13990/products/spectra/fullrun_ccd2_acisf13990_pi14-548_pass1_cl_src19.wrmf not found [Fri May 17 20:31:07 2013] Removal of ../../acisf13990/products/spectra/fullrun_ccd2_acisf13990_pi14-548_pass1_cl_src19.soff failed [Fri May 17 20:31:52 2013] Spectrum 19 has only 6 counts, deleting rmf [Fri May 17 20:31:52 2013] 167.732 [Fri May 17 20:41:28 2013] Updating aperture counts using extracted products [Fri May 17 20:41:28 2013] Total counts from fullrun_ccd2_acisf13990_pi14-548_pass1_cl_src19_src.pi.gz = 8.00 [Fri May 17 20:41:28 2013] Total counts from fullrun_ccd2_acisf13990_pi14-548_pass1_cl_src19_bgd.pi.gz = 29.00 [Fri May 17 20:41:28 2013] Got source and background scale factors 0.000003, 0.000061 [Fri May 17 20:41:28 2013] User source parameters: Position = (177.5, 180.5) = 3 17 3.73 42 13 33.4 Extent = 1.3" x 0.7", rotation angle = 121 Source aperture counts = 6.7 +/- 4.0 Background aperture counts = 1.3 Rate = 0.0002 +/- 0.0001 [Fri May 17 20:41:28 2013] Updating counts from extracted products [Fri May 17 20:41:28 2013] Set source signif. to 6.70/1.14 = 5.87 [Fri May 17 20:41:28 2013] Calculating source flux in energy range 0.30-8.00 [Fri May 17 20:41:28 2013] Using photon index=1.80, rate=0.000181, arf fullrun_ccd2_acisf13990_pi14-548_pass1_cl_src19.arf [Fri May 17 20:41:28 2013] Assuming count rate is from the 0.20-8.00 bandpass [Fri May 17 20:41:28 2013] Updating source flux to 2.4e-15 [Fri May 17 20:41:36 2013] Simple spatial fitting not done (or not done successfully), skipping spectral fitting [Fri May 17 20:41:37 2013] acisf13990/analysis//spectral/fullrun_ccd2_acisf13990_pi14-548_pass1_cl_src19_pl.csv not found, spectral fit skipped or did not complete