[Tue May 14 10:34:38 2013] Detection parameters: Position = (515.5, 688.0) = 1 35 9.21 37 56 58.2 Extent = 0.5" x 0.5", rotation angle = 27 degrees Source counts = 1.9 +/- 1.4 Background counts = 0.1 Rate = 0.0002 +/- 0.0001 [Tue May 14 10:34:38 2013] Off-axis axis estimate = 4.65' [Tue May 14 10:57:04 2013] Using EEF radius (= 1.05 ")to estimate initial spatial extent for simple fitting [Tue May 14 10:57:04 2013] Initial guess for spatial extent in simple fitting = 1.05" [Tue May 14 10:57:04 2013] Spatial fitting skipped for pass 0: source has 1.9 net counts, is at off-axis angle 4.7' [Tue May 14 11:17:57 2013] Vigneting correction estimate = 1.000000 [Tue May 14 11:17:57 2013] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue May 14 11:17:57 2013] Assessing source extent using major [Tue May 14 11:17:57 2013] Source does appear to be extended [Tue May 14 11:17:57 2013] Computing asymmetry using major and minor axis, asym = 1.00 [Tue May 14 11:31:29 2013] Using EEF radius (= 1.05 ")to estimate initial spatial extent for simple fitting [Tue May 14 11:31:29 2013] Initial guess for spatial extent in simple fitting = 1.05" [Tue May 14 11:31:29 2013] Spatial fitting skipped for pass 1: source has 1.9 net counts, is at off-axis angle 4.7' [Tue May 14 11:55:52 2013] Vigneting correction estimate = 1.000000 [Tue May 14 11:55:52 2013] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Tue May 14 11:55:52 2013] Assessing source extent using major [Tue May 14 11:55:52 2013] Source does appear to be extended [Tue May 14 11:55:52 2013] Computing asymmetry using major and minor axis, asym = 1.00 [Tue May 14 11:55:52 2013] Deleting source due to low Poisson probability 0.7