[Thu Aug 8 13:41:49 2013] Detection parameters: Position = (356.0, 49.2) = 15 48 31.58 -48 23 14.4 Extent = 0.6" x 0.5", rotation angle = 3 degrees Source counts = 3.9 +/- 2.0 Background counts = 0.1 Rate = 0.001 +/- 0.0006 [Thu Aug 8 13:41:49 2013] Off-axis axis estimate = 1.80' [Thu Aug 8 14:13:40 2013] Using EEF radius (= 0.41 ")to estimate initial spatial extent for simple fitting [Thu Aug 8 14:13:40 2013] Initial guess for spatial extent in simple fitting = 0.41" [Thu Aug 8 14:13:40 2013] Spatial fitting skipped for pass 0: source has 3.9 net counts, is at off-axis angle 1.8' [Thu Aug 8 14:15:10 2013] Vigneting correction estimate = 1.000000 [Thu Aug 8 14:15:10 2013] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Thu Aug 8 14:15:10 2013] Assessing source extent using major [Thu Aug 8 14:15:10 2013] Source does appear to be extended [Thu Aug 8 14:15:10 2013] Computing asymmetry using major and minor axis, asym = 1.13 [Thu Aug 8 14:55:09 2013] Using EEF radius (= 0.41 ")to estimate initial spatial extent for simple fitting [Thu Aug 8 14:55:09 2013] Initial guess for spatial extent in simple fitting = 0.41" [Thu Aug 8 14:55:09 2013] Spatial fitting skipped for pass 1: source has 3.9 net counts, is at off-axis angle 1.8' [Thu Aug 8 14:57:40 2013] Vigneting correction estimate = 1.000000 [Thu Aug 8 14:57:40 2013] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Thu Aug 8 14:57:40 2013] Assessing source extent using major [Thu Aug 8 14:57:40 2013] Source does appear to be extended [Thu Aug 8 14:57:40 2013] Computing asymmetry using major and minor axis, asym = 1.13 [Thu Aug 8 14:58:24 2013] Writing source region out to fullrun_ccd7_acisf13805_pi14-548_pass1_cl_src5_src.reg [Thu Aug 8 14:58:24 2013] Extracting stamp from image fullrun_ccd7_acisf13805_pi14-548_cl_sm2.00.img.gz, (331, 24) - (381, 75) [Thu Aug 8 14:58:24 2013] Writing fullrun_ccd7_acisf13805_pi14-548_pass1_cl_src5.gif [Thu Aug 8 14:59:14 2013] Size of ../../acisf13805/products/events/fullrun_ccd7_acisf13805_pi14-548_pass1_cl_src5_src.evt.gz[events] = 4 counts [Thu Aug 8 14:59:14 2013] Mean chipx,y = (31.75, 359.25) [Thu Aug 8 14:59:14 2013] Mean tdetx,y = (3948.75, 2061.25) [Thu Aug 8 14:59:14 2013] chipx,y range = (14.00-41.00, 344.00-374.00) [Thu Aug 8 14:59:14 2013] Size of ../../acisf13805/products/events/fullrun_ccd7_acisf13805_pi14-548_pass1_cl_src5_bgd.evt.gz[events] = 1 counts [Thu Aug 8 14:59:15 2013] Not generating rmf since there are only 3 counts [Thu Aug 8 14:59:15 2013] arf not found, will run specextract [Thu Aug 8 14:59:22 2013] ../../acisf13805/products/spectra/fullrun_ccd7_acisf13805_pi14-548_pass1_cl_src5.warf not found [Thu Aug 8 14:59:22 2013] ../../acisf13805/products/spectra/fullrun_ccd7_acisf13805_pi14-548_pass1_cl_src5.wrmf not found [Thu Aug 8 14:59:22 2013] Removal of ../../acisf13805/products/spectra/fullrun_ccd7_acisf13805_pi14-548_pass1_cl_src5.soff failed [Thu Aug 8 14:59:46 2013] Spectrum 5 has only 4 counts, deleting rmf [Thu Aug 8 14:59:46 2013] 228.862 [Thu Aug 8 14:59:48 2013] Updating aperture counts using extracted products [Thu Aug 8 14:59:48 2013] Total counts from fullrun_ccd7_acisf13805_pi14-548_pass1_cl_src5_src.pi.gz = 4.00 [Thu Aug 8 14:59:48 2013] Total counts from fullrun_ccd7_acisf13805_pi14-548_pass1_cl_src5_bgd.pi.gz = 1.00 [Thu Aug 8 14:59:48 2013] Got source and background scale factors 0.000001, 0.000011 [Thu Aug 8 14:59:48 2013] User source parameters: Position = (356.0, 49.2) = 15 48 31.58 -48 23 14.4 Extent = 0.6" x 0.5", rotation angle = 3 Source aperture counts = 3.9 +/- 3.2 Background aperture counts = 0.1 Rate = 0.001 +/- 0.0009 [Thu Aug 8 14:59:48 2013] Updating counts from extracted products [Thu Aug 8 14:59:48 2013] Set source signif. to 3.92/0.27 = 14.31 [Thu Aug 8 14:59:48 2013] Calculating source flux in energy range 0.30-8.00 [Thu Aug 8 14:59:48 2013] Using photon index=1.80, rate=0.00115, arf fullrun_ccd7_acisf13805_pi14-548_pass1_cl_src5.arf [Thu Aug 8 14:59:48 2013] Assuming count rate is from the 0.20-8.00 bandpass [Thu Aug 8 14:59:48 2013] Updating source flux to 1.1e-14 [Thu Aug 8 14:59:53 2013] Simple spatial fitting not done (or not done successfully), skipping spectral fitting [Thu Aug 8 14:59:54 2013] acisf13805/analysis//spectral/fullrun_ccd7_acisf13805_pi14-548_pass1_cl_src5_pl.csv not found, spectral fit skipped or did not complete