[Sun Jun 2 22:20:03 2013] Detection parameters: Position = (106.8, 143.3) = 15 54 32.68 -55 5 2.4 Extent = 0.5" x 0.5", rotation angle = 146 degrees Source counts = 6.0 +/- 3.6 Background counts = 7.0 Rate = 4e-05 +/- 2e-05 [Sun Jun 2 22:20:03 2013] Off-axis axis estimate = 0.56' [Mon Jun 3 01:41:43 2013] Using EEF radius (= 0.39 ")to estimate initial spatial extent for simple fitting [Mon Jun 3 01:41:43 2013] Initial guess for spatial extent in simple fitting = 0.39" [Mon Jun 3 01:41:43 2013] Spatial fitting skipped for pass 0: source has 6.0 net counts, is at off-axis angle 0.6' [Mon Jun 3 02:37:12 2013] Vigneting correction estimate = 1.000000 [Mon Jun 3 02:37:12 2013] Source flux estimate in the 0.3-8.0 bandpass, Gamma=1.800000 = 0 [Mon Jun 3 02:37:12 2013] Assessing source extent using major [Mon Jun 3 02:37:12 2013] Source does appear to be extended [Mon Jun 3 02:37:12 2013] Computing asymmetry using major and minor axis, asym = 1.00 [Mon Jun 3 02:37:12 2013] Deleting source due to low Poisson probability 0.8